int. PS - Internal power stage, motor, encoder
Limit
Voltage
Limitation voltage
à
int. PS
à
Motor
Encoder
‘0x8F00-02 - Encoder actual value’
‘0x8680-02 - Power section supply
voltage actual value’ on page 137
‘0x8680-08 - Control voltage power
stage actual value’ on page 138
PI
PI current controller
‘0x8600-02 - Current actual value’
4.9 Deployment I/O1...I/O4
The module has 4 digital connectors I/O1...I/O4. The ports can be used with the following
configurable modes:
n
Used as digital input
n
Used as digital output
n
Pairs use as encoder input for 24V HTL signal
The 4 digital ports of the motion module have the following default settings:
Default setting
Pos.
Function
Type
Description
3
I/O1
I
Digital input
4
I/O3
I
Digital input
7
I/O2
I
Digital input
8
I/O4
I
Digital input
I: Input, O: Output
Via
Chapter 5.2.5 ‘Digital inputs I/O1...I/O4 - 0x7100’ on page 103
respectively
Chapter 5.2.6 ‘Digital output I/O1...I/O4 - 0x7200’
on page 105 the 4 digital pins of the motion modules can be configured.
Digital input: DC 24V
IEC 61131-2 type 3
High-side (sink)
Overview
Default settings
Connections
VIPA System SLIO
Deployment
Deployment I/O1...I/O4
HB300 | FM | 054-1CB00 | en | 18-06