Always adapt parameters to the operating mode!
Please ensure that the module always has the correct parameters
according to the selected operating mode! Pay special attention to the
use of the current values in the output area!
Start parameter
–
‘Start - Start parameter homing’ on page 54
–
‘Start - Start parameter PtP position profile’ on page 62
–
‘Start - Start parameter velocity profile’ on page 73
–
‘Start - Start parameter torque control’ on page 77
1.
Perform for your System SLIO and your motion module a hardware configuration
and create your application program. Transfer both into your CPU. A separate para-
metrization of the motion module is not required.
2.
Power supply
The module is to be power supplied with the both DC 24V voltages
power section supply I/O area and electronic power supply. When
commissioning these may simultaneously or electronic power
supply must be switched on first. When commissioning these may
simultaneously or power section supply I/O area must be switched
Switch your CPU to RUN state.
3.
Switch on the motor.
ð
Your system is now ready for communication and you can establish parameter
setting via the
Acyclic channel
.
4.
Send the command "Shutdown".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: x110
ð
The motion module shows the state
‘Ready to switch on’
.
5.
Send the command "Switch on".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 0111
ð
The motion module shows the state
‘Switched on’
.
6.
Send the command "Enable operation".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 1111
ð
The motion module shows the state
‘Operation enabled’
. The drive is now
ready for your move commands.
Steps of commissioning
VIPA System SLIO
Deployment
Commissioning > Start-up of the System SLIO motion module
HB300 | FM | 054-1CB00 | en | 18-06
48