1.
Chapter 4.2 ‘Commissioning’ on page 47
Homing objects
Chapter 5.2.11 ‘Homing - 0x8300’ on page 119
2.
n
Switch the state machine to state
‘Switch on disabled’
–
Send the command "Disable voltage"
‘0x8100-01 - Control word’ on page 109
Bit 3...0: xx0x:
ð
The motion module shows the state
‘Switch on disabled’
.
3.
Set the following parameters:
n
‘0x8300-02 - Homing method’ on page 119
–
Enter the value 17.
n
‘0x8300-03 - Homing digital input I/O1…I/O4’ on page 120
–
Select the input to which the homing switch is connected.
n
‘0x8300-04 - Homing digital input active polarity I/O1…I/O4’ on page 120
–
Define the polarity of the switch
n
‘0x8300-05 - Homing target position’ on page 121
–
Define by specifying a target position the maximum axis movement path,
that during movement the homing switch is passed over.
n
‘0x8300-06 - Homing velocity V1’ on page 121
–
Specify the high velocity for the movement to the homing switch.
n
‘0x8300-07 - Homing velocity V2’ on page 121
–
Specify the low velocity for the movement to the homing switch.
n
‘0x8300-08 - Homing acceleration’ on page 122
–
Specify the acceleration for homing.
n
‘0x8300-09 - Homing deceleration’ on page 122
–
Specify the deceleration for homing.
n
‘0x8300-10 - Homing offset value’ on page 122
–
If necessary specify an offset for the homing position.
4.
n
‘0x8400-03 - Positioning profile target velocity’ on page 123
–
Enter the value 0.
5.
n
Switch your motion module to the
Positioning
Operating mode requested’ on page 118
–
Enter the value 1.
6.
Send the command "Shutdown"
‘0x8100-01 - Control word’ on page 109
Bit 3...0: x110:
ð
The motion module shows the state
‘Ready to switch on’
.
7.
Send the command "Switch on".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 0111
ð
The motion module shows the state
‘Switched on’
.
8.
Send the command "Enable operation".
‘0x8100-01 - Control word’ on page 109
Bit 3...0: 1111
ð
The motion module shows the state
‘Operation enabled’
. The drive is now
ready for your move commands.
9.
n
Switch your motion module to the
Homing
mode.
Operating mode requested’ on page 118
–
Enter the value 6.
ð
The drive starts homing. Upon completion of the homing, the position of the ref-
erence switch is used as the reference point.
Proceeding
VIPA System SLIO
Deployment
Homing > Homing by means of a homing switch
HB300 | FM | 054-1CB00 | en | 18-06
56