4.7 Velocity profile
Always adapt parameters to the operating mode!
Please ensure that the module always has the correct parameters
according to the selected operating mode! Pay special attention to the
use of the current values in the output area!
Start parameter
–
‘Start - Start parameter homing’ on page 54
–
‘Start - Start parameter PtP position profile’ on page 62
–
‘Start - Start parameter velocity profile’ on page 73
–
‘Start - Start parameter torque control’ on page 77
In the operation mode
Velocity profile
the velocity is output according to profile accelera-
tion and profile deceleration until the target velocity is reached. This operation mode
bases on the
PtP positioning profile
, except that position settings such as target and limit
values have no effect. With this object
‘0x8500-01 - Velocity control configuration’
, you can specify the frequency pulse patterns.
Start: Start parameters
Limit Velocity: Limitation velocity
Limit Current: Limitation current
Limit Voltage: Limitation voltage
Vel: Velocity profile
Vel control: Velocity control
PtP: PtP positioning profile
Position control: Position controller
PI: PI current controller
int. PS: Internal power stage
M: Motor
Encoder: Encoder current value
Structure
VIPA System SLIO
Deployment
Velocity profile
HB300 | FM | 054-1CB00 | en | 18-06
72