Auto Shutoff ..........................................................................17
Resetting the System Setup Menu to Factory Default ......17

Calibration  .........................................................................................18

Temperature .........................................................................18
Barometer .............................................................................18
Dissolved Oxygen ................................................................19
pH Calibration ......................................................................22
ORP Calibration ....................................................................24

Taking Measurements .......................................................................24

Dissolved Oxygen ................................................................25
pH/ORP ..................................................................................25

Saving and Viewing Data ..................................................................25

Saving Data ...........................................................................26
Viewing and Erasing Saved Data ........................................26

Care, Maintenance and Storage ......................................................28

General Maintenance ..........................................................28
Sensor Maintenance ............................................................29
Sensor Storage .....................................................................35

Troubleshooting ................................................................................36

Specifications .....................................................................................39

Accessories / Part Numbers .............................................................39

Declaration of Conformity ................................................................41

Recycling ............................................................................................42

Battery Disposal ...................................................................42

Contact Information ..........................................................................42

Ordering and Technical Support ........................................42
Service Information ..............................................................43

W A R R A N T Y

The YSI Professional 1020 instrument (Pro1020) is warranted for three (3) 
years from date of purchase by the end user against defects in materials 
and workmanship, exclusive of batteries and any damage caused by 
defective batteries. Pro1020 cable assemblies are warranted for two (2) 
years from date of purchase by the end user against defects in material and 
workmanship. Pro1020 Polarographic, pH and ORP sensors are warranted 
for one (1) year from date of purchase by the end user against defects in 
material and workmanship. Pro1020 Galvanic sensors are warranted for 
six (6) months from date of purchase by the end user against defects in 
material and workmanship. Pro1020 instruments & cables are warranted 
for one (1) year from date of purchase by the end user against defects in 
material and workmanship when purchased by rental agencies for rental 
purposes. Within the warranty period, YSI will repair or replace, at its sole 
discretion, free of charge, any product that YSI determines to be covered 
by this warranty.

To exercise this warranty, call your local YSI representative, or contact YSI 
Customer Service in Yellow Springs, Ohio at +1 937 767-7241, 800-897-
4151 or visit YSI.com for a Product Return Form. Send the product and 
proof of purchase, transportation prepaid, to the Authorized Service 
Center selected by YSI. Repair or replacement will be made and the 
product returned, transportation prepaid.  Repaired or replaced products 
are warranted for the balance of the original warranty period, or at least 90 
days from date of repair or replacement.

LIMITATION OF WARRANTY

This Warranty does not apply to any YSI product damage or failure caused 
by: 
1.  Failure to install, operate or use the product in accordance with YSI’s 

written instructions; 

2.  Abuse or misuse of the product; 
3.  Failure to maintain the product in accordance with YSI’s written 

instructions or standard industry procedure; 

4.  Any improper repairs to the product; 
5.  Use by you of defective or improper components or parts in servicing 

or repairing the product; 

6.  Modification of the product in any way not expressly authorized by YSI.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. YSI’S LIABILITY UNDER THIS WARRANTY 
IS LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, AND THIS 
SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY DEFECTIVE 
PRODUCT COVERED BY THIS WARRANTY. IN NO EVENT SHALL YSI BE 
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES RESULTING FROM ANY DEFECTIVE PRODUCT COVERED BY 
THIS WARRANTY.

Содержание YSI Pro1020

Страница 1: ...USER MANUAL English Fran ais Espa ol Portugu s Pro1020 User Manual DOCUMENT 605187...

Страница 2: ...1 Battery Installation 1 Key Pad 2 Connecting the Sensor and Cable 3 Membrane Installation 6 Run Screen 7 Backlight 7 Powering Off 7 Navigation 7 First Power On 8 System Setup Menu 9 DO Local 10 Last...

Страница 3: ...YSI will repair or replace at its sole discretion free of charge any product that YSI determines to be covered by this warranty To exercise this warranty call your local YSI representative or contact...

Страница 4: ...arts or materials are damaged or missing contact YSI Customer Service at 800 897 4151 1 937 767 7241 or the authorized YSI distributor from whom the instrument was purchased BATTERY INSTALLATION The i...

Страница 5: ...he bottom of the Run screen and to increase numerical inputs 3 Power and Backlight Press once to turn instrument on Press a second time to turn backlight on Press a third time to turn backlight off Pr...

Страница 6: ...Next remove the o ring and slide the lid off the sensor INSTALLING THE DISSOLVED OXYGEN SENSOR Before installing a sensor or connecting the cable to the instrument the Sensor Type must be configured f...

Страница 7: ...cap from the dissolved oxygen sensor by pulling it straight off Thoroughly rinse the sensor tip with distilled or deionized water Fill the cap membrane 3 4 full of electrolyte solution then tap the ca...

Страница 8: ...dissolved oxygen sensor type and membrane type Use the up or down arrow keys to highlight the appropriate language sensor and membrane then press enter to confirm figure 6 The Sensor Type must be con...

Страница 9: ...instead of during calibration Example Instrument 1 with DO Local enabled At 737 mmHg barometric pressure roughly 841 ft above sea level the instrument would calibrate to 100 When taking measurements...

Страница 10: ...ompatible sensors for use with a field cable Polarographic This sensor has a black sensor body and is engraved with the model number 2003 Polarographic will be abbreviated Polaro in the instrument men...

Страница 11: ...lay steadily and the instrument will beep twice if Audio is turned on DO Auto Stable can be set to a change of 0 0 to 1 9 over 3 to 19 seconds ISE Auto Stable can be set to a change of 0 0 to 9 9 over...

Страница 12: ...nge the language Highlight the desired language English Spanish Portuguese or French and press enter to enable The enabled language will have an X in the box next to it Highlight the ESC Exit box and...

Страница 13: ...ate formula for this uncorrection is True BP Corrected BP 2 5 Local Altitude in ft above sea level 100 Although the Pro1020 barometer range is 400 0 to 999 9 mmHg you can not adjust the value across t...

Страница 14: ...ubleshooting guide for possible solutions CALIBRATING IN PERCENT DO LOCAL ENABLED Perform this calibration procedure when DO Local is enabled and Quick DO Cal is disabled in the System Setup menu 1 Pe...

Страница 15: ...5 If necessary use the up and down arrow keys to adjust the pH buffer value Note the pH mV reading which ideally should be between 50 and 50 in buffer 7 6 Press enter to continue to second point 7 Ri...

Страница 16: ...membrane If using the 1001A amplified pH sensor be sure to use the guard extender supplied in the 605216 amplified pH sensor kit The extender is screwed onto the sensor bulkhead before the guard or c...

Страница 17: ...enter to regain access to scrolling through the saved data The data set displayed is indicated by the data set number 01 through 50 ERASING DATA While viewing saved data press the enter key to access...

Страница 18: ...or connector Check the o ring and the groove for any excess grease or contamination If contamination is evident clean the o ring and nearby plastic parts with lens cleaning tissue or equivalent lint f...

Страница 19: ...the sensor in clean water wipe with a cotton swab saturated with clean water not DI water and then rerinse with clean water To be certain that all traces of the acid are removed i from the sensor cre...

Страница 20: ...d in the membrane kit Do not sand the electrodes every membrane change as this is not routine maintenance In fact visually the anode may appear tarnished and operate properly YSI recommends using the...

Страница 21: ...embrane should be changed if a bubbles are visible under the membrane b dried electrolyte is visible around the membrane and c if the sensor shows unstable readings or other sensor related symptoms Th...

Страница 22: ...em for service Symptom Possible Solution Instrument will not calibrate pH or ORP instrument displays Calibration Over Calibration Under or Unstable Reading during calibration 1 Verify correct ISE sens...

Страница 23: ...specifications represent typical performance and are subject to change without notice For the latest product specification information please visit YSI s website at ysi com or contact YSI Tech Suppor...

Страница 24: ...E blue cap 6 each includes electrolyte Used with Galvanic sensor All cables include a temperature sensor The pH or ORP and Dissolved Oxygen sensors are sold separately D E C L A R AT I O N O F C O N F...

Страница 25: ...country and region and users are expected to understand and follow the battery disposal requirements for their specific locale C O N TA C T I N F O R M AT I O N ORDERING AND TECHNICAL SUPPORT Telephon...

Страница 26: ...Item 605187 Rev A January 2014 2014 YSI Incorporated...