R E C Y C L I N G

YSI is committed to reducing the environmental footprint in the course 
of doing business. Even though materials reduction is the ultimate 
goal, we know there must be a concerted effort to responsibly deal 
with materials after they’ve served a long, productive life-cycle. YSI’s 
recycling program ensures that old equipment is processed in an 
environmentally friendly way, reducing the amount of materials going 
to landfills. 

• 

Printed Circuit Boards are sent to facilities that process and reclaim 
as much material for recycling as possible.

• 

Plastics enter a material recycling process and are not incinerated 
or sent to landfills.

• 

Batteries are removed and sent to battery recyclers for dedicated 
metals. 

When the time comes for you to recycle, follow the easy steps outlined 
at www.ysi.com.

BATTERY DISPOSAL

The Pro1020 is powered by alkaline batteries which the user must 
remove and dispose of when the batteries no longer power the 
instrument. Disposal requirements vary by country and region, and 
users are expected to understand and follow the battery disposal 
requirements for their specific locale.
 

C O N T A C T   I N F O R M A T I O N

ORDERING AND TECHNICAL SUPPORT

Telephone:  

800 897 4151 (USA)

  +1 

937 

767 

7241 

(Globally) 

    

 

 

Monday through Friday, 8:00 AM to 5:00 ET

Fax:  

 

+1 937 767 9353 (orders) 

 

 

 

 

 

 

+1 937 767 1058 (technical support)

Email:    

[email protected]

Mail: 

 

 YSI 

Incorporated      

  1725 

Brannum 

Lane 

     

 

 

Yellow Springs, OH 45387 

 

  USA
Internet:  

ysi.com

When placing an order please have the following available:
1.)  YSI account number (if available) 
2.)  Name and phone number 
3.)  Purchase Order or Credit Card number
4.)  Model Number or brief description
5.)  Billing and shipping addresses
6.)  Quantity 

SERVICE INFORMATION

YSI has authorized service centers throughout the United States and 
Internationally.  For the nearest service center information, please visit 
ysi.com and click ‘Support’ or contact YSI Technical Support directly at 
800-897-4151 (+1 937-767-7241).

When returning a product for service, include the Product Return form 
with cleaning certification. The form must be completely filled out for a 
YSI Service Center to accept the instrument for service. The form may 
be downloaded from ysi.com.  

Содержание YSI Pro1020

Страница 1: ...USER MANUAL English Fran ais Espa ol Portugu s Pro1020 User Manual DOCUMENT 605187...

Страница 2: ...1 Battery Installation 1 Key Pad 2 Connecting the Sensor and Cable 3 Membrane Installation 6 Run Screen 7 Backlight 7 Powering Off 7 Navigation 7 First Power On 8 System Setup Menu 9 DO Local 10 Last...

Страница 3: ...YSI will repair or replace at its sole discretion free of charge any product that YSI determines to be covered by this warranty To exercise this warranty call your local YSI representative or contact...

Страница 4: ...arts or materials are damaged or missing contact YSI Customer Service at 800 897 4151 1 937 767 7241 or the authorized YSI distributor from whom the instrument was purchased BATTERY INSTALLATION The i...

Страница 5: ...he bottom of the Run screen and to increase numerical inputs 3 Power and Backlight Press once to turn instrument on Press a second time to turn backlight on Press a third time to turn backlight off Pr...

Страница 6: ...Next remove the o ring and slide the lid off the sensor INSTALLING THE DISSOLVED OXYGEN SENSOR Before installing a sensor or connecting the cable to the instrument the Sensor Type must be configured f...

Страница 7: ...cap from the dissolved oxygen sensor by pulling it straight off Thoroughly rinse the sensor tip with distilled or deionized water Fill the cap membrane 3 4 full of electrolyte solution then tap the ca...

Страница 8: ...dissolved oxygen sensor type and membrane type Use the up or down arrow keys to highlight the appropriate language sensor and membrane then press enter to confirm figure 6 The Sensor Type must be con...

Страница 9: ...instead of during calibration Example Instrument 1 with DO Local enabled At 737 mmHg barometric pressure roughly 841 ft above sea level the instrument would calibrate to 100 When taking measurements...

Страница 10: ...ompatible sensors for use with a field cable Polarographic This sensor has a black sensor body and is engraved with the model number 2003 Polarographic will be abbreviated Polaro in the instrument men...

Страница 11: ...lay steadily and the instrument will beep twice if Audio is turned on DO Auto Stable can be set to a change of 0 0 to 1 9 over 3 to 19 seconds ISE Auto Stable can be set to a change of 0 0 to 9 9 over...

Страница 12: ...nge the language Highlight the desired language English Spanish Portuguese or French and press enter to enable The enabled language will have an X in the box next to it Highlight the ESC Exit box and...

Страница 13: ...ate formula for this uncorrection is True BP Corrected BP 2 5 Local Altitude in ft above sea level 100 Although the Pro1020 barometer range is 400 0 to 999 9 mmHg you can not adjust the value across t...

Страница 14: ...ubleshooting guide for possible solutions CALIBRATING IN PERCENT DO LOCAL ENABLED Perform this calibration procedure when DO Local is enabled and Quick DO Cal is disabled in the System Setup menu 1 Pe...

Страница 15: ...5 If necessary use the up and down arrow keys to adjust the pH buffer value Note the pH mV reading which ideally should be between 50 and 50 in buffer 7 6 Press enter to continue to second point 7 Ri...

Страница 16: ...membrane If using the 1001A amplified pH sensor be sure to use the guard extender supplied in the 605216 amplified pH sensor kit The extender is screwed onto the sensor bulkhead before the guard or c...

Страница 17: ...enter to regain access to scrolling through the saved data The data set displayed is indicated by the data set number 01 through 50 ERASING DATA While viewing saved data press the enter key to access...

Страница 18: ...or connector Check the o ring and the groove for any excess grease or contamination If contamination is evident clean the o ring and nearby plastic parts with lens cleaning tissue or equivalent lint f...

Страница 19: ...the sensor in clean water wipe with a cotton swab saturated with clean water not DI water and then rerinse with clean water To be certain that all traces of the acid are removed i from the sensor cre...

Страница 20: ...d in the membrane kit Do not sand the electrodes every membrane change as this is not routine maintenance In fact visually the anode may appear tarnished and operate properly YSI recommends using the...

Страница 21: ...embrane should be changed if a bubbles are visible under the membrane b dried electrolyte is visible around the membrane and c if the sensor shows unstable readings or other sensor related symptoms Th...

Страница 22: ...em for service Symptom Possible Solution Instrument will not calibrate pH or ORP instrument displays Calibration Over Calibration Under or Unstable Reading during calibration 1 Verify correct ISE sens...

Страница 23: ...specifications represent typical performance and are subject to change without notice For the latest product specification information please visit YSI s website at ysi com or contact YSI Tech Suppor...

Страница 24: ...E blue cap 6 each includes electrolyte Used with Galvanic sensor All cables include a temperature sensor The pH or ORP and Dissolved Oxygen sensors are sold separately D E C L A R AT I O N O F C O N F...

Страница 25: ...country and region and users are expected to understand and follow the battery disposal requirements for their specific locale C O N TA C T I N F O R M AT I O N ORDERING AND TECHNICAL SUPPORT Telephon...

Страница 26: ...Item 605187 Rev A January 2014 2014 YSI Incorporated...

Отзывы: