Table 48: RX AFE ports (cont'd)
Ports
Dir
Clock Domain
Description
BGRCALOVRD[4:0]
In
Async
Reserved. This port must be set to
5’b11111
. Do not modify this value.
BGRCALOVRDENB
In
Async
Reserved. This port must be set to
1’b1
.
Do not modify this value.
RCALENB
In
Async
Reserved. This port must be set to
1’b1
.
Do not modify this value.
The following table defines the RX AFE attributes.
Table 49: RX AFE Attributes
Attribute
Type
Description
CH[0/1]_RX_PAD_CFG0
16-bit
Reserved.
Bit Name
Address
Description
PAD_RTERM_VCOM_MODE
[12:11]
Controls the mode for the RX termination voltage:
2’b00
: AVTT
2’b01
: Reserved
2’b10
: Floating
2’b11
: Programmable
PAD_RTERM_VCOM_LVL
[10:7]
Controls the common mode in programmable mode:
4’b0000
: 100 mV
4’b0001
: 200 mV
4’b0010
: 250 mV
4’b0011
: 300 mV
4’b0100
: 350 mV
4’b0101
: 400 mV
4’b0110
: 500 mV
4’b0111
: 550 mV
4’b1000
: 600 mV
4’b1001
: 700 mV
4’b1010
: 800 mV
4’b1011
: 850 mV
4’b1100
: 900 mV
4’b1101
: 950 mV
4’b1110
: 1000 mV
4’b1111
: 1100 mV
GTM Use Modes - RX Termination
This section describes the GTM use modes with RX termination.
Chapter 4: Receiver
UG581 (v1.0) January 4, 2019
Virtex Ult GTM Transceivers
86