Basic Installation Procedures
51
Freedom SW-RVC Installation Guide
Step 8: Testing Your Installation
WARNING
ELECTRICAL SHOCK HAZARD
Do not use the INVERTER ENABLE button on the Freedom
SW-RVC to de-energize the unit. This button and buttons on
optional accessories, such as the RV-C system device
controller, if available, do not disconnect DC or AC power
sources to the Freedom SW-RVC.
Failure to follow these instructions can result in death or serious
injury.
There are several tests to be performed for testing your
installation. These tests will verify that:
n
the Freedom SW-RVC works in invert mode
n
the Freedom SW-RVC works in charge mode
n
the Freedom SW-RVC works in AC bypass mode
If the test fails at any point, go to
Step 7: Performing Checks Prior
to Initial Start-Up on page 50
and go through the checklist again to
check the installation. Then perform the test again. If the test fails
again, see the troubleshooting section in the Owner's Guide
(document number: 975-1056-01-01).
Figure 13 Freedom SW-RVC Front Panel
RV-C INTERFACE
STACKING
FREEDOM
SW
INVERTER/CHARGER
CLEAR FAULT
RESET
INVERTER
ENABLE
INVERTER
ENABLED
AC IN
FAULT
GEN
SUPPORT
CHARGING WARNING
Содержание 815-3012-02
Страница 14: ...This page is intentionally left blank 2 ...