Basic Installation Procedures
39
Freedom SW-RVC Installation Guide
Connecting the AC Output Wires
NOTICE
EQUIPMENT DAMAGE
Do not connect the output of the inverter to any AC source.
Failure to follow these instructions can result in equipment
damage.
To make the AC output wiring connections:
1. Remove one of the AC knockouts from the front or side of
the unit. Do not leave the knockout inside the wiring
compartment.
2. The applicable installation code may not allow you to run
the AC input and AC output wiring through the same AC
knockout.
3. Install a strain-relief clamp in the AC knockout and run the
AC wiring through the strain-relief clamp.
4. Strip approximately 2 inches (50 mm) off the jacket from the
AC cable and separate the wires.
5. Using a 1/4" blade slot screwdriver, loosen the terminal
screws on the AC output terminals. Do not remove the
screws.
6. Connect the line and neutral wires to the output terminals
(labeled AC Output on the terminal block,
) as follows:
Terminals
Line for Dual Output
Lines for Single Output
N2
Neutral 2
Unused
L2
Line 2
Unused
N1
Neutral 1
Neutral
L1
Line 1
Line
7. Tighten the terminal screws. Leave some slack wire inside
the wiring box.
8. Connect the ground wires to a free position on the ground
bus,
. If solid ground wire is being used,
the wire can be connected directly under the screw heads.
If stranded ground wire is being used, ring terminals must
also be used.
9. Secure the strain-relief clamp on the AC output cable
jacket.
10. Attach the wiring compartment cover panel and tighten the
four screws.
11. Connect the outgoing AC wires to an AC load panel
equipped with circuit breakers.
Содержание 815-3012-02
Страница 14: ...This page is intentionally left blank 2 ...
Страница 75: ...This page is intentionally left blank 2 ...