48
Flex Fuel Owner’s Manual
March 2011
Cover the cardboard with a layer of small bulk materi-
als that covers the entire bottom of the firebox.
12: Bulk Materials Auto Mode
12.4 Setting the Release Period
Note: It is particularly important that you determine whether sufficient power demand is available
prior to the firing process. First check the temperatures in your buffer tank(s) to allow you to deter-
mine when to set the release periods.
Note: The draft inducer fan must be switch off before the release period can be set.
Once the furnace has been filled, it is possible to set a release period during which automatic ignition
should take place. If the start screen is not displayed, press the ESC button until it appears.
FLEX FUEL
V 10.060 Tu, 12.09.10
Bulk materials
Boiler temperature:
Flue gas temperature:
Air factor:
Stop system!
XXXºF
13:44
XXXºF
X.XX
Now you can fill the entire firebox with medium to
large size bulk materials for a full load, or fill as need-
ed. Ensure the fuels is in a tightly packed group that
is parallel to the firebox walls. Ensure that the fuel will
not bind on the walls and can move freely.