43
March 2011
Flex Fuel Owner’s Manual
Smoldering gas extraction! Please add more!
Smoldering gas extraction is activated. You can now add more bulk material. Press the ESC button for
3 – 4 seconds to deactivate smoldering gas extraction. Smoldering gas extraction is automatically
deactivated after several minutes.
Fan lag! Please wait!
Fan lag is activated for approximately 20 minutes after a power outage or when the safety temperature
limiter (STL) has been reset. The status will immediately change to “Bulk materials!” if any active
combustion is detected in the firebox during this lag period. Detection is based on the flue gas
temperature or air factor.
You cannot abort Fan Lag.
11.7 Indications
Your WoodMaster dealer can undertake pre settings so that the system operator receives various
instructions at the display. These instructions are not to be understood as a furnace malfunction or fault.
The instructions are solely to alert the system operator of possible erratic behavior.
The following instructions are possible:
When firing is not necessary
This instruction is displayed if the system operator wants to ignite the furnace and the buffer tank(s) is
(are) already full. Before firing, it is recommended that the buffer temperatures are checked. If the
temperature is still sufficient, it is recommended you postpone firing until later.
When filling is not necessary
(smoldering gas extraction is activated by the system operator)
This instruction is displayed if the system operator wants to activate smoldering gas extraction and the
buffer tank(s) is (are) already full.
11: Bulk Materials Mode
No
NOTE!
The buffer tank is already
full! Only increase firing
when sufficent demand is
assured!
Do you still wish to increase
firing?
No
NOTE!
The buffer tank is already
full! A boiler filling is only
reccommended when sufficent
demand is assured!
Do you still wish to add more?