10
Flex Fuel Owner’s Manual
March 2011
5: Installation
Your Flex fuel must be installed by a professional and should follow all local, state and federal laws
and regulations. Any use of an unapproved installation may result in a voided warranty.
It is recommended to have your installation approved by WoodMaster.
5.1 Location
Your Flex fuel can only be installed indoors where the temperature will not fall below 50
°
F. The furnace
may be installed inside the building that it serves or in an out building. Your Flex fuel must not be
allowed to freeze. Your Flex fuel does not need to be installed in the same structure that it serves.
Ensure that the floor that the furnace is placed on is level and able to support the weight of the furnace
plus the additional weight of the water and fuel.
There should be ample room around your Flex fuel to make loading and cleaning your furnace easier.
This area should also be clear of any easily combustible materials. Minimum clearances requirements is
11 inches for the top, 14 inches for the sides, 19.5 inches for the back and open to the front.
The room where the furnace is placed should allow ample venting to ensure proper air flow to the
furnace. The vent size requirements are 31 square inches for the Flex fuel 30 kW and 62 square inches for
the Flex fuel 60 kW.
Ensure the feet are in the bottom of the furnace. adjust the feet so the furnace sits level and the feet are
loaded evenly.
Below are the dimensions for both the Flex fuel 30 kW and Flex fuel 60 kW including all optional
accessories and chimney.
Chimney Mount
Pellet Tank
Pellet A
uger
Ig
nit
er
15.00
17.00
R14.00
R4.00
57.00
40.00
38.00
28.25
11.25
4.25
24.00
58.25
6.25
Chimney Mount
Pellet Tank
Pellet A
uger
Ig
nit
er
15.50
19.00
R14.00
R5.00
53.00
51.00
30.00
72.00
13.00
4.25
32.50
71.00
66.75
6.25
62.50
30 kW
60 kW