Flex Fuel Owner’s Manual
March 2011
9.8 Output Test – Heating Cycle
Note: Output tests may be preformed by the owner, however, damage can occur if preformed
incorrectly. Please contact your WoodMaster Flex fuel dealer for assistance.
An output test of all connected pumps and mixers can be performed in this menu, in order to be able to
test the correct operating method.
Note: The heating cycle program is interrupted, as long as the output test is performed.
The heating cycle output test should only be controlled by a professional.
Move the curser by turning the control knob to the output test – heating cycle line and press the control
knob. Following figure will appear on the screen:
You can now press the control knob to scroll through the items to select one to change. If the control
knob is turned to the right while the cursor is in the heading, then the menu “Output Test 2-heat cycle”
appears for more options. You may turn the control knob again to bring up the “Output Test 3-heat cycle”
menu.
Switching on the Outputs
Press the control knob and the cursor moves from the header to the first menu item mixer 1. By turning
the control knob, select the output that you would like to activate and press the control knob. The cursor
changes to the entry field. You can switch the output on and/or off by turning the control knob. The
input options change from Off to Open to Close in the entry fields of mixer 1 and mixer 2.
Press the control knob in order to save the selection and/or to leave the input field. The cursor now
changes back to the respective menu item. You can now switch another output on and/or off or exit the
menu by pressing the ESC key.
9.9 Output Test – Boiler
Note: Damages may occur to the furnace, for which the manufacturer is not liable, in the event of
an incorrect use of “Output test – boiler”. The outputs should never be activated too long, since this
may result in blocking the screw and therefore in blocking the respective motor. Please contact your
WoodMaster Flex fuel dealer for assistance.
Note: This menu is only visible when the status line is “Boiler is switched off!”.
All functions of important components of the furnace can be tested in this menu.
Output test 1-heat cycle
Heat cycle pump 1:
Heat cycle pump 2:
Heat cycle pump 3:
Heat cycle pump 4:
Heat cycle pump 5:
Heat cycle pump 6:
Heat cycle pump 7:
Heat cycle pump 8:
DHWR pump 1:
DHWR pump 2:
DHWR pump 3:
DHWR pump 4:
Off
Off
Off
Off
Off
Off
Off
Off
9: Basic Furnace Settings