29
March 2011
Flex Fuel Owner’s Manual
9.5 Setting the Clock/Date
Note: There is no automatic conversion for daylight saving time.
Note: This furnace runs on DD/MM/YY date format and on military time format.
Once you have selected this menu item, the clock stops and the following figure appears on the screen.
9.6 Service Menu
The service menu includes factory settings designed to provide ideal combustion characteristics. These
settings have already been optimized in the factory. Access to these settings can only be obtained by
your dealer. Please contact your WoodMaster Flex fuel Dealer for assistance.
9.7 Alarm Protocol
All malfunctions are chronologically listed in the alarm protocol. The alarm protocol menu can be found
in the service menu main page and selecting it will bring up the following screen:
When pressing the control knob on the alarm protocol screen, the symbol LEFT/RIGHT appears in the
upper right hand corner and all previous alarms can be scrolled through.
Note: 40 entries are stored. After the 40th entry (alarm number 39), the oldest entry with alarm
number 0 is deleted. It will store when the error message was triggered and when it was cancelled.
Therefore, there are 2 entries in the alarm protocol per error message.
9: Basic Furnace Settings
Set CLOCK/DATE
Date: 10.09.10
Time: 17:05
ALARM PROTOCOL
Alarm number: 37
Type of alarm: acknowl.
Date: 10.12.09
Clock: 10:20:27
SAFETY TEMPERATURE LIMITER
HAS TRIPPED!
Please reset the safety
temperature limiter once the
boiler has cooled down
then press START!
ALARM PROTOCOL
Alarm number: 30
Type of alarm: triggered
Date: 10.12.09
Clock: 10:10:13
MAIN FUSE FAULTY!
Follow the instructions in the
operating manual and replace
the main fuse!
The boiler will be operational
again once its run-on time has
expired!