64
Enclosure 1: Installation and Operating Instructions
•
Move forward through the installation
instructions by pushing the function knob (1).
•
Observe the operating instructions carfully!
•
Use correct nozzle!
•
For natural gas use nozzle N, 08!
•
For propane / butane gas use nozzle P, 06!
•
Tighten all gas connections (left-hand
thread) with a wrench.
•
Do NOT seal up the gas conection of the
burner with Teflon tape or similar.
•
Maximum inlet pressure natural gas: 27 mbar.
•
Maximum inlet pressure propane / butane
gas: 57.5 mbar.
•
To open gas supply: turn knob
counterclockwise.
•
To open air intake: pull knob outwards and
turn counterclockwise.
•
General burner operations by pushing &
turning.
•
Switching on & off / resetting by long push.