Let’s take a closer look at the various parts of this form, starting with the right side of
the form. At the top we see an ID box that we can use to scroll through the events. This is
followed by a
Name
field, where the event is given a name. To the right of that is an
Event
Type
drop down box, where the type of event will be selected. Note that, in the picture,
the
Event Type
is blank, and the tabbed area below displays a tab titled
Undefined
. The
tabbed area title and contents will change depending on the type of event selected. When
the
Event Properties
form is first viewed by clicking the
New
button on the main screen,
or selecting
Events>New
from the menu, this is how the form will look. We will take a
closer look at the various event type tabs later.
Worthy of note is the text displayed on the
Undefined tab. This defines what is required
before an event being created is accepted by the software. If you try to proceed from the
currently viewed event to another by clicking
Apply
or
OK
, you will not be able to proceed
unless certain information is furnished. The event must have an
Event Type
specified, must
have at least one
Day
box checked, and must have a
Name
assigned.
Note that you can get away with not assigning signals to a Connect or Disconnect
Event; however, such events will do nothing when fired.
The left side of the dialog, at the top, gives you the tools for specifying when an event
will fire. The
Start Time
specifies the first time on a checked
Day
that the event will fire.
Enter the time in 12 hour mode, and specify
AM
or
PM
.
The
Repeat Interval
determines how often an event will fire on a checked
Day
. The
Repeat Interval
is specified in hours and minutes. As an example, if the
Repeat Interval
is specified to be 4 hours and 30 minutes, and the
Start Time
is 2:15:00 PM, the event can
be expected to fire on a checked day at 2:15, 6:45, and 11:15 (all these are PM times).
There are separate check boxes for each day of the week,
Sunday
through
Saturday
.
Events will not be fired on days that are not checked. For convenience, the
Check All Days
and
Uncheck All Days
buttons are provided, with rather obvious consequences. The Invert
Selection button checks all unchecked
Day
boxes and unchecks all checked
Day
boxes.
The
1‑Time‑Only
check box is a little less obvious. When this box is checked, once an
event fires it is deleted from the list. However, if the box is not checked, the fired event is
added at the bottom of the schedule, one week later in time than when it just fired.
Below the schedule settings are two buttons used to enter the event in the
Event Manager
list.
OK
enters the current event in the list and closes the
Event Properties
dialog, while
Apply
adds the current event to the list but leaves the
Event Properties
dialog in place. A
third button,
Cancel
, er – ah – cancels the event, and it is not added to the list.
Advancing the previously described
ID
spin box without first clicking
Apply
on the
current event results in a prompt that asks you to decide if you want to apply changes
before viewing the next event.
The previously discussed
Request Config
button on the left side of the dialog at the
bottom is used to fetch signals from a connected BLADE 3.
View Events
The
Event Properties
dialog shows you the properties of the event currently being
viewed. As mentioned above, the tabbed area will change depending on the
Event Type
.
Let’s look at this a little more closely.
Содержание WheatNet-IP BLADE3
Страница 2: ...Technical Manual Wheatstone Corporation Jan 2016 Audio Over IP Network WheatNet IP BLADE3 ...
Страница 16: ...Quick Start 12 WheatNet IP BLADE 3 Jan 2016 Figure 4 ...
Страница 274: ...page A 48 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 4 External Controllers A 49 ...
Страница 290: ...page A 61 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Click Next Click Install ...
Страница 336: ...page A 107 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 9 Introduction to Screen Builder A 108 ...
Страница 338: ...page A 109 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S ...
Страница 365: ...WheatNet IP BLADE 3 June 2018 page A 136 A P P E N D I C E S Some Screen Shots of Various Vendors Configuration Screens ...
Страница 366: ...WheatNet IP BLADE 3 June 2018 page A 137 A P P E N D I C E S ...