page 4 – 9
WheatNet-IP BLADE 3
/ Jan 2016
E T H E R N E T N E T W O R K S A N D S W I T C H E S
the surface will connect, along with the Surface IP Address (on the default 192.168.87.
xxx scheme), Subnet Mask, and Gateway.
If Automatic mode is selected, enter the Mix Engine ID of the WheatNet‑IP Mix
Engine to be associated with the surface and remaining settings are configured for you.
You can manually enter this information by pressing the Manual button and using the
numbered keypad on the screen. Pressing NEXT will advance to the next field.
For convenience, Wheatstone uses the following convention for IP Addressing in the
WheatNet‑IP system:
1. The IP Address of a BLADE 3 is equal to the BLADE 3 ID plus 100; i.e.,
BLADE 3 3 = 192.168.87.103
2. The IP Address of an E‑6 control surface is equal to the Engine BLADE 3 ID plus
200; i.e., Engine BLADE 3 = 5, Surface IP Address = 192.168.87.205
When done simply press APPLY to finalize these settings and the surface will request
a reboot.
Select YES from the dialog box and the surface will reboot.
Содержание WheatNet-IP BLADE3
Страница 2: ...Technical Manual Wheatstone Corporation Jan 2016 Audio Over IP Network WheatNet IP BLADE3 ...
Страница 16: ...Quick Start 12 WheatNet IP BLADE 3 Jan 2016 Figure 4 ...
Страница 274: ...page A 48 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 4 External Controllers A 49 ...
Страница 290: ...page A 61 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Click Next Click Install ...
Страница 336: ...page A 107 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 9 Introduction to Screen Builder A 108 ...
Страница 338: ...page A 109 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S ...
Страница 365: ...WheatNet IP BLADE 3 June 2018 page A 136 A P P E N D I C E S Some Screen Shots of Various Vendors Configuration Screens ...
Страница 366: ...WheatNet IP BLADE 3 June 2018 page A 137 A P P E N D I C E S ...