Now that you are in the Global configuration mode you need to select the interface
that you would like to configure. We’ll start with the default VLAN.
The switch will come with a default VLAN enabled. In the default configuration all
ports on the switch have been assigned to VLAN1 (DEFAULT_VLAN). The command
below selects the default VLAN for configuration to segment network traffic on the switch.
If you are adding an additional VLAN to existing hardware, substitute that VLAN number
in place of 1.
Enter the following commands (“XXX” = the actual network IP address)
Vlan1
ip address 192.168.87.XXX 255.255.255.0
end
Let’s look at what you just setup. By typing “Vlan1” you are entering the configuration
for that VLAN. The “IP Address” Command simply sets the IP address of the VLAN1
interface for remote management purposes. The IP address must be unique on the network.
IGMP Querier Configuration
By default, IGMP is disabled globally on the switch. To setup IGMP Multicast filtering
on the switch you must be in the Global configuration mode. To enter the configuration
mode once again type “Config T” and press enter.
Enter the following commands:
ip igmp
ip igmp querier
end
The commands above simply enable IGMP on the default VLAN and the querier on
the switch.
Configuring Gigabit Ports Connecting to WheatNet-IP I/O BLADE 3s
and PC Drivers
Configuring the ports on the HP Procurve Series 2810 is a key step in ensuring optimal
performance of the WheatNet‑IP network. This section will guide you in the setup of each
port used for WheatNet‑IP I/O BLADE 3s.
To setup ports on the switch you must also be in the Global Configuration mode. To
enter the configuration mode once again type “Config T” and press enter.
Enter the following commands
Interface X (X=the Ethernet port being configured)
speed 1000-FULL
end
Ports on the HP Procurve can be configured individually or in a “Range.” If range is
desired type
Interface 1 - 24 (for example), using the desire number of ports.
Содержание WheatNet-IP BLADE3
Страница 2: ...Technical Manual Wheatstone Corporation Jan 2016 Audio Over IP Network WheatNet IP BLADE3 ...
Страница 16: ...Quick Start 12 WheatNet IP BLADE 3 Jan 2016 Figure 4 ...
Страница 274: ...page A 48 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 4 External Controllers A 49 ...
Страница 290: ...page A 61 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Click Next Click Install ...
Страница 336: ...page A 107 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S Contents Appendix 9 Introduction to Screen Builder A 108 ...
Страница 338: ...page A 109 WheatNet IP BLADE 3 Jan 2016 A P P E N D I C E S ...
Страница 365: ...WheatNet IP BLADE 3 June 2018 page A 136 A P P E N D I C E S Some Screen Shots of Various Vendors Configuration Screens ...
Страница 366: ...WheatNet IP BLADE 3 June 2018 page A 137 A P P E N D I C E S ...