Weidmuller Wireless Ethernet Modem and Device Server User Manual
3
Rev Version 1.1
•
The Wireless Ethernet module is intended to be installed in a final enclosure, rated IP54, before use outdoors.
•
The Equipment shall be powered using an external listed power supply with LPS outputs or a Class 2 power
supply.
•
The Wireless Ethernet module must be properly grounded for surge protection before use.
•
If installed in a hazardous location, coaxial cable shall be installed in a metallic conduit
Hazardous Location Notices
This equipment complies with the following standards:
•
IEC 60079-0:2011
•
IEC 60079-15:2010
This equipment complies with 94/9/EC - ATEX Directive Ex nA IIC T4 Gc
–40 °C ≤ Ta ≤ +70 °C.
WARNING: EXPLOSION HAZARD
Do not disconnect equipment unless power has been switched off or the area is known to be
non- hazardous.
Special Condition: This equipment is designed to be installed as a component in an enclosure that meets IP54.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D; Tamb
–40˚C to +70˚C or
non-hazardous locations only.
This equipment must be powered by a suitable certified Class II power supply.
When being installed in a Class I, Division 2 hazardous area, this equipment must be installed in a suitable
enclosure such that a tool is required to gain access to the connectors external to the certified equipment.
If installed in a hazardous location, the antenna shall be located outside of the hazardous area.
GNU Free Documentation License:
Copyright (C) 2009 WEIDMULLER.
WEIDMULLER is using a part of Free Software code under the GNU General Public License in operating the
WI-MOD-xxx-E-5W product. This General Public License applies to most of the Free Software
Foundation’s code
and to any other program whose authors commit by using it. The Free Software is copyrighted by Free Software
Foundation, Inc., and is licensed
“as is” without warranty of any kind. Users are free to contact WEIDMULLER for
instructions on how to obtain the source code used in the WI-MOD-xxx-E-5W.
A copy of the license is included in Appendix H.
Important Notice
WEIDMULLER products are designed to be used in industrial environments, by experienced industrial
engineering personnel with adequate knowledge of safety design considerations.
WEIDMULLER radio products are used on unprotected license-free radio bands with radio noise and interference.
The products are designed to operate in the presence of noise and interference. However, in an extreme case radio
noise and interference could cause product operation delays or operation failure. Like all industrial electronic
products, WEIDMULLER products can fail in a variety of modes due to misuse, age, or malfunction. We recommend
that users and designers design systems using design techniques intended to prevent personal injury or damage
during product operation, and provide failure tolerant systems to prevent personal injury or damage in the event of
product failure. Designers must warn users of the equipment or systems if adequate protection against failure has
not been included in the system design.