4 - Lubricate and Assemble the Stitch Head - Check the Position of the Wire-holder - front-to-back
G8 Stitch Head Maintenance Kit Instructions
91
Step
Action
Information
1
Remove the wire-holder from the
stitch head.
Discard the piece of stitch-wire.
2
Loosen but do not remove the
grub-screw.
3
Loosen the lock nut and adjust the
position of the eccentric adjuster
screw.
4
Tighten the grub-screw.
5
Tighten the lock nut and fit the
wire-holder to the stitch head.
Hold the eccentric adjuster screw
in position when you tighten the
lock nut.
6
Repeat the check and adjustment
procedure until the wire-holder is
in the correct position.
7
Make sure there is no stitch-wire
loaded in the wire-holder.