Reassembly - Install Discharge
Determining Impeller Rotation
1. The assembly of the discharge components varies slightly based on Pump Model and input rotation.
2. The input rotation of the drive end of the pump determines the direction the pump impeller rotates.
3. If you are unsure of the impeller rotation of your pump, the cast rotation arrow on the pump body can be used to determine which rotation configuration
you have. The pump model can be obtained from the serial plate attached to the pump intake fitting. Compare your pump to the diagrams below.