background image

 

 

 

Full details of terms and conditions are available on request from: - 

 

APPLIED ENERGY PRODUCTS LIMITED, 

MORLEY WAY, PETERBOROUGH PE2 9JJ 

TEL +44 (0) 844 372 7750 / FAX: +44 (0) 844 372 7760 

Website: www.applied-energy.com

 

 

       

(A4 Leaflet No. 578-2018-12a) 

 

     

            

  

 

 

 

Point of Use Water Heater 

Installation & Instruction Manual 

 

THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS  

(INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL 

CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY 

HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE 

 OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. 

 

CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY 

 DO NOT PLAY WITH THE APPLIANCE. 

 

 

These instructions should be read in full before commencing the installation.                                                
We recommend that the installation should only be carried out by a suitably qualified 

person. 

 

The 

Redring WS7-EcoT

 heater is an open outlet, thermal storage water heater for use 

with Redring recommended fittings for one outlet only. 
It operates on the displacement principle i.e. when cold water is admitted into the 

bottom of the tank, hot water flows out through the outlet.  

 
Installation 

 

We recommend that this unit should be installed in the following order: 

 

1.

 

Fit wall bracket. 

 

2.

 

Fit mains electrical cable to the unit.  

 

3.

 

Fit heater to the wall. 

 

4.

 

Connect plumbing to the unit. 

 

5.

 

Replace the front cover. 

 

6.

 

Fill the unit with water and check for leaks. 

 

7.

 

Connect mains electrical cable to the fixed wiring. 

 

8.

 

Set the weekly mechanical timer. 

 

9.

 

Turn unit on and check operation. 

 

10.

 

Demonstrate operation to user. 

 

Please Note:- 
When removing the front cover, we recommend that you first remove the two top fixing 
screws, but only LOOSEN the two bottom screws. 
This will aid when replacing the front cover during installation. 

 

 

 
 
 
 
 

 

 
 

Содержание WS7-EcoT

Страница 1: ...n should only be carried out by a suitably qualified person The Redring WS7 EcoT heater is an open outlet thermal storage water heater for use with Redring recommended fittings for one outlet only It operates on the displacement principle i e when cold water is admitted into the bottom of the tank hot water flows out through the outlet Installation We recommend that this unit should be installed i...

Страница 2: ...the wiring rules 6 The cable should be heat resisting 3 core flexible PVC of 1 25mm minimum 7 Installation Engineer Note The most likely reason for no heated water is an open circuit thermal fuse See label on front insulation for details This can be caused at initial commissioning if the heating element is energized with no water in the tank Alternatively it may be due to a back siphonage in the c...

Страница 3: ...to cool or that any hot water is run through the heater before commencing this operation The heater must be disconnected from the electrical supply before commencing this operation Take care to protect the mechanical programmer from any water If the unit fails to heat water 1 Check that the switching time on the mechanical programmer is set to be ON 2 Check that the mechanical programmer is not in...

Страница 4: ... hours and 20 minutes A major benefit of the Redring WS7 EcoT heater is the energy saving possibilities of controllability and the facility in a commercial installation to set a programme to cover a weekly usage pattern including weekends However the thick insulation contained in the Redring WS7 EcoT heater also ensures economic running costs if the heater is left on at all times Setting up the we...

Отзывы: