Reassembly - Install PIV (Priming Isolation Valve)
Assemble PIV (Priming Isolation Valve)
(Required only if PIV requires overhaul)
1. Install the piston seal in the groove in the piston.
2. Install the valve seal on the piston with the pan head screw and washer.
3. Install the two (2) rod seals and O-ring in internal grooves in the valve body.
4. Install the piston in the valve body.
5. Install the wave spring from the internal bore in the valve body.
6. Install the priming valve cover with the two button head screws and
washers.
1. Install O-rings in the internal grooves in the pump body and PIV body.
2. Install priming tube in the PIV body.
3. Install PIV body/tube assembly in pump body while engaging the PIV
body on the priming tube clip.
4. Connect air line to push-on fitting retaining ring in and hold while pushing
the air line in.
Install PIV (Priming Isolation Valve)
PIV Body
PIV Body O-ring,
3/4 x 1 in.
Tube
Pump Body O-ring,
3/4 x 1 in.
Priming Tube Clip
Push-On
Fitting
PIV Body
Pan Head Screw
and Washer
Piston
Piston Seal
Priming Valve Cover
Two Button Head Screws
Rod Seals
Valve Seal
Wave Spring
Содержание HL Series
Страница 52: ...F 1031 Section 4321 Page 52 of 57 Reassembly Cross Section Views HL200D and HL300D Direct Drive Models...
Страница 53: ...F 1031 Section 4321 Page 53 of 57 HL200K and HL300K Gear Drive Models...
Страница 54: ...F 1031 Section 4321 Page 54 of 57 HL400D Direct Drive Model...
Страница 55: ...F 1031 Section 4321 Page 55 of 57 HL400K Gear Drive Model...