F
−
1031, Section 4321
Page 15 of 57
Disassembly - Remove Impellers
Main Stage Impellers
1. Restrain the companion flange on drive end of pump to prevent movement.
2. Remove locknut and washer from end of shaft.
3. Remove impeller from shaft. The M8-1.75 tapped holes in the impeller may be used to pull the impeller off the shaft.
4. Remove the O-ring in the groove on the back side of the impeller.
5. Remove the O-ring from the groove in the shaft.
Impeller O-ring
Shaft O-ring
Shaft O-ring
Impeller O-ring
Main Stage Impeller
Locknut
Содержание HL Series
Страница 52: ...F 1031 Section 4321 Page 52 of 57 Reassembly Cross Section Views HL200D and HL300D Direct Drive Models...
Страница 53: ...F 1031 Section 4321 Page 53 of 57 HL200K and HL300K Gear Drive Models...
Страница 54: ...F 1031 Section 4321 Page 54 of 57 HL400D Direct Drive Model...
Страница 55: ...F 1031 Section 4321 Page 55 of 57 HL400K Gear Drive Model...