WL2 FW
Manual
Page 63 – Revision EU05-07-17
9.
Dispenses Hot and Cold Water at the same time
Possible Reason
Solution
Too much water pressure.
Recommend 2.7 to 4 bar for
the
WL2FW Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 2.7-4bar.
Hot or Cold solenoid is stuck
open.
Remove Top Cover.
Check Hot Solenoid: Dispense cold water and visually inspect tubing
for water flow from both tanks.
Check Cold Solenoid: Disconnect Elbow from outlet of Cold
Solenoid. Select hot water and dispense (quickly releasing
Dispensing Button to avoid much water coming out of Cold Solenoid.
Replace Solenoid as necessary.
10.
No Cold Water Available
Possible Reason
Solution
Too much water pressure.
Recommend 2.7 to 4 bar for
the
WL2FW Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 2.7-4bar.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...