Closed Water Supply Valve
Open the Water Supply Valve
Cold Water Solenoid Valve
malfunction
Inspect the valve components for proper functionality.
Red Heater & Compressor
Switch on unit is off.
If water is dispensing at room temperature:
Turn Red Heater & Compressor Switch on.
I =ON
Loose connection(s) on the
Display PCB
Turn power off; unplug the
WL2FW Water Treatment System
and
visually inspect solenoid connections into the Display PCB. Verify
the soldering points on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.
Water Pressure is too high
Ensure input water pressure is between 2.7-4bar; Install pressure
reducer or regulator.
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.