Energy Saver PCB
Relay Board
Connector Bad
Inspect connector for discoloration.
If there is no discoloration, contact Waterlogic
Technical Department.
Thermostat or
overheat “open” on
Hot Tank
Turn Power off. Check OHM’s resistance across terminals on each
Thermostat and Overheat separately.
Good components will indicate a closed circuit (continuity) or zero OHM’s on
the meter.
Replace components as necessary.
Loose or improperly
Visually inspect wire leads gong to the hot tank; confirm proper connections
to the heating elements.
Hot tank life is 3-5 years, depending on usage.
connected wire(s) to
the Heating Element
/ Hot Tank.
Heating Coil Not
Heating
Turn Power off; Drain hot tank; Use multi-meter to check Heater Element for
continuity up to 96.8Ω
–
115.2Ω resistance.
Hot Tank must be empty if you are checking for continuity.
Replace Hot Tank as necessary.
The unit has been changed to a cold/ambient setting (JP9 has been moved
from Pin 1 and Pin 2).
Improper Jumper
Settings
Verify that Jumper Pins are located properly for Hot Water Option.
See Changing Hot Water Mode to Ambient Water Instructions included
further below in this Troubleshooting Section
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...