WL2 FW
Manual
Page 30 – Revision EU05-07-17
No
Description
1
15W UV Lamp Assembly
Recommend stocking 10 for
every 10 machines
2
Quartz Spiral for Firewall
Recommend stocking 10 for
every 10 machines
3
GAC Filter - 10" Carbon
Activated Inline Filter –
Optional
Not
Shown
Carbon Block - 10" CBC 1 Micron
Lead and Cyst Reduction Inline
Filter –
Optional
4
Solenoid Valve 1000mm
(recommend replacing Solenoid
Cushion at same time)
Recommend stocking 2 for every
10 machines
4.1
Solenoid Cushion
Recommend stocking 2 for every
10 machines
5
Hot Water Faucet
Recommend stocking 2 for every
10 machines
6
Main PCB
Recommend stocking 4 for every
10 machines
7
Silicon Button Key Mat
Recommend stocking 5 for every
10 machines
8
Button Label
Recommend stocking 2 for every
10 machines
9
Drip Tray Grill – Charcoal
Recommend stocking 4 for every
10 machines
10
Drip Tray - Charcoal with
Waterlogic Logo
Recommend stocking 4 for every
10 machines
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...