WL2 FW
Manual
Page 52 – Revision EU05-07-17
2.
FAULT CODE:
Green Flashing Light and 15 second Audible Alarms –Indicates the
Firewall UV system is not detecting adequate dose of UV to ensure safe water.
*The Cold Solenoid will shut down and no cold water will dispense. Hot water will
still dispense.
Possible Reason
Solution
Firewall UV System does not
have adequate dose of UV.
Check UV System
1.
If Ballast Indication Light is Green – the system should
be operational. Ensure UV lamp is on. Replace Lamp.
If lamp is replaced and problem persists, replace UV
Sensor.
2.
If Ballast Indication Light is Red, change UV Lamp.
3.
If Ballast Indication Light is not lit – check power to
Ballast. If power is going to Ballast – replace Ballast.
Remove Cover to locate Ballast
Power to Ballast
Wiring Harness to UV Lamp
Ballast Indication Light
N = Black Wire
1 = White Wire
L = White Wire (Live)
2 = White Wire
3 = Yellow Wire
4 = Yellow Wire
Flashing Green Light
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...