background image

WL2 FW 

Manual

 

Page 43 – Revision EU05-07-17

 

 

 

 

PRE-DELIVERY PROCEDURES

 

 

   

DANGER!  

ELECTRICAL SHOCK HAZARD.

 

Only qualified personnel who have read and understand this entire manual should attempt to

 

install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug 

into an electrical supply until specifically instructed.

 

   

WARNING!  

ALWAYS SANITIZE BEFORE USE.

 

Sanitize before use to eliminate any potential microbiological contaminates.

 

 

Materials Needed:

 

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear

 

 

Phillips Screwdriver.  Temperature Gauge.

 

 

Water Pitcher or Container to collect water from the faucet

 

 

3 Litre container or drain basin

 

 

Aquadosa Sanitizer – Or equivalent (5.25% Sodium Hypochlorite)

 

 

1/4”O.D. Plastic Tubing, at least 1.5m in length, and assorted 1/4” quick connect fittings.

 

 

Test Strips for measuring sanitizer levels

 

 

TDS Meter (Optional)

 

1.

 

Unpack the 

Waterlogic WL2FW Water Treatment Systems 

and check exterior for damage.

 

Sanitizing

 

 

Sanitize Aquadosa or other approved sanitizing cleaner throughout the cold and or ambient 

circuits. Follow all instructions on the sanitizer and flush with fresh water through the faucet 

until odour and taste is acceptable.

 

  

WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Always ensure proper ventilation and use proper personal protective equipment such as gloves 

and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific 

requirements of each chemical product. Take all necessary precautions to prevent sanitizer 

from contacting eyes, clothing, and any other surfaces in could damage (carpets).

 

2.

 

We recommend using Aquadosa sanitizer, 60ml dose is enough to sanitize the machine. See 

manufactures instructions for any other sanitizing solution used. Measure and insert 60ml 

Aquadosa into the Sanitizing Cartridge. Always ensure sanitizer is compatible with stainless steel 

and acetyl plastic.

 

3.

 

Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of 

unit.  Turn on water supply.

 

 

4.

 

Connect power to 

WL2FW Water Treatment System

. DO NOT TURN ON RED 

COMPRESSOR & HEATER SWITCH AT THIS TIME. 

O=OFF

 

Содержание WL2FL Free Standing

Страница 1: ...ted Second Floor Suite 4 Beacon Court Sandyford Co Dublin Ireland Tel 353 0 1293 1960 Fax 353 0 1293 1052 For Technical Support Email support waterlogicsupport zendesk com WLI UK LTD Global Headquarte...

Страница 2: ...ication is written for use by these qualified individuals Waterlogic encourages users to learn about products however we believe that product knowledge and service is best obtained by consulting Water...

Страница 3: ...h Limit Safety 15 Hot Tank Descaling 17 Programming Disabling Energy Saving Sleep Mode 19 Programming Changing from Hot Tank Thermostat to Thermistor 20 Programming Changing Hot Water Mode to Ambient...

Страница 4: ...roperly earthed outlet Unit should be protected by residual current device RCD having a rated residual operating current not exceeding 30mA Use only Waterlogic supplied power cord Never use extension...

Страница 5: ...reduce microbiological contamination potential bacterial growth Sanitize before use to eliminate any potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for household use only Neve...

Страница 6: ...tive barrier against microbes like bacteria and mould which may cause odours or staining Large Dispense Area with Recessed Faucet 200mm dispense height with BioCote recessed faucet to protect from cro...

Страница 7: ...characteristics of microbiological water purifiers The requirements are based on the recommendations of the U S Environmental Protection Agency s Task ForceReport NSF ANSI 42 Chlorine Taste and Odour...

Страница 8: ...FICATIONS ITEM WL2FL Mini WL2FL Free Standing Power Supply 220V 50Hz or 120V 60Hz Water Connection Quick Connect Cold Water Temperature Cold Water Temperature Factory Set Point 5 C 41 F Cold Tank Size...

Страница 9: ...14 5 x 41 Weight dry 26 3 kg 58 pounds 30 kg 66 pounds ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 220V 50Hz or 120V 60Hz 13 Amp Service 220V 50Hz 15 Amp Service 120V 60Hz COMPONENT POWER approximate...

Страница 10: ...Water Select Button followed by the DispensingButton within 3 seconds For Hot Water Press Hot Water Select Button followed by the DispensingButton within 3 seconds NOTE Default selection mode is Cold...

Страница 11: ...efore removing UV Lamp CAUTION UV LAMPS ARE HAZARDOUS Lamps are considered Hazardous Waste and must be disposed of accordingly Refer to Product MSDS sheet fordetails 3 Clean the Spiral Quartz Sleeve t...

Страница 12: ...m any high pressure down to 3bar 0 5bar The pressure reducing valve is an essential part of the installation rail and ensures that the Waterlogic Water Treatment System is not exposed to high pressure...

Страница 13: ...tube that allows air and water to pass into the vent chamber as it is heated Water in the vent chamber is suctioned back through the outlet tube vent hole when water is dispensed Expansion of water as...

Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...

Страница 15: ...on the rear of the hot tank As you look through the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treatment System reac...

Страница 16: ...top flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor Heater Switch I...

Страница 17: ...stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Protective Equipment Rubber or Nitrile Safety Gloves and ProtectiveEyewear Phillips...

Страница 18: ...ure the WL2FW Water Treatment System is performing to the customer s satisfaction WARNING HOT WATER The WL2FW Water Treatment System produces Hot Water up to 87 C 189 F Water above 52 C 125 F can caus...

Страница 19: ...any button wakes up the WL2FW Water Treatment System and turns the heater circuit back on The hot tank will typically take less than 10 minutes to heat the water from ambient to the 85 C 185 F set poi...

Страница 20: ...istor Control is for a future Hot Tank design Do not change to Thermistor or it will disable the Hot Tank Unplug Power Cord and remove Top Cover to access Heater Control PCB 1 2 3 Pin Numbers Heater C...

Страница 21: ...FW Water Treatment Systems comes defaulted with Hot Cold water which can be changed to Ambient Cold settings DF1 settings default is to Hot Cold Unplug Power Cord and remove Top Cover to access Energy...

Страница 22: ...20v 60Hz HT 3042 HT 3041 Replace every 3 to 5 years depending on usage 1 Micron CBC Cyst Lead Reduction Filter Assembly NSF 53 FT 0063 Local water conditions will determine proper filter type and main...

Страница 23: ...WL2 FW Manual Page 22 Revision EU05 07 17 WL2FW MINI DRAWING AND PARTS LIST Wetted Parts Green Recommended spare parts Yellow Consumables...

Страница 24: ...0mm recommend replacing Solenoid Cushion at same time Recommend stocking 2 for every 10 machines 4 1 Solenoid Cushion Recommend stocking 2 for every 10 machines 5 Hot Water Faucet Recommend stocking 2...

Страница 25: ...heat Metal Cover Recommend stocking 2 for every 10 machines 13 Overheat with Manual reset 105 C 221 F Recommend stocking 2 for every 10 machines 14 Hot Tank Thermostat 87 C 187 F Recommend stocking 2...

Страница 26: ...22 Energy Saver PCB 23 Electric Ballast Bracket 24 Firewall UV Relay PCB 25 JG 1 4 Stopper PI0808S used with Bulkhead Union x John Guest P N PI1208S Mini Only 26 Bulkhead Union x John Guest P N PI120...

Страница 27: ...32 2 UVC Sensor Fixing Metal Bracket Back 37 Front Upper Insert Panel 38 Firewall PCB Cover 39 Silver Front Panel for Drip Tray Insert Firewall 40 JG 3 8 x 1 4 Reducing Fitting PI211208S 41 Firewall...

Страница 28: ...wer Line Noise Filter Electromagnetic Interference filter EMI 50 Fuse Holder Fuse 220V 10A with only one wire Fuse Holder Fuse 120V 15A with only one wire 51 Red Compressor Heater Switch 52 Silver Bac...

Страница 29: ...lter Clip 60 Flow Restrictor 1 8 mm hole Not Shown Firewall UV Female Wire Connector Not Shown Wire Connector between Hot Tank and Thermostat Not shown Power Cord EU 220V 50Hz Power Cord UK 220V 50Hz...

Страница 30: ...WL2 FW Manual Page 29 Revision EU05 07 17 WL2FW FREE STANDING DRAWING AND PARTS LIST Wetted Parts Green Recommended spare parts Yellow Consumables...

Страница 31: ...0mm recommend replacing Solenoid Cushion at same time Recommend stocking 2 for every 10 machines 4 1 Solenoid Cushion Recommend stocking 2 for every 10 machines 5 Hot Water Faucet Recommend stocking 2...

Страница 32: ...rmostat and Overheat Metal Cover Recommend stocking 2 for every 10 machines 13 Overheat with Manual reset 105 C 221 F Recommend stocking 2 for every 10 machines 14 Hot Tank Thermostat 87 C 187 F Recom...

Страница 33: ...Firewall Free Standing Transformer 120V 1A for Firewall Free Standing 23 UVC Sensor Wire 2FW 24 CDS Fixing Rubber Silicon 25 Firewall UV Lamp Rubber 26 Spiral Rubber Buffer 27 Firewall Mark IV Stainle...

Страница 34: ...ront Bottom Insert Panel Free Standing Only 33 Filter Bracket Free Standing Only 34 2 8 Filter Clip 35 Unit Rubber Feet Free Standing Only 36 Bottom Tray 37 Leak Tray Free Standing Only 38 Leak Contai...

Страница 35: ...1 Cold Thermostat Cover Label 44 2 Wire Connector between Hot Tank and Thermostat 45 Socket Power Line Noise Filter Electromagnetic Interference filter EMI 46 Fuse Holder Fuse 220V 10A with only one...

Страница 36: ...Saver PCB 53 JG LLD PE Tube Blue O D 1 4 John Guest P N PE 08 BI 1000F B 54 Flow Restrictor 1 8 mm hole 55 Silicon Tube 5 16 for Hot Water Not shown Power Cord EU 220V 50Hz Power Cord UK 220V 50Hz Po...

Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...

Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...

Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...

Страница 40: ...age 39 Revision EU05 07 17 WL2FW ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians should attempt live tes...

Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...

Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...

Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...

Страница 44: ...mage Sanitizing Sanitize Aquadosa or other approved sanitizing cleaner throughout the cold and or ambient circuits Follow all instructions on the sanitizer and flush with fresh water through the fauce...

Страница 45: ...s upon your water quality and your water usage For example if there is a lot of sediment and or particles in your water then you will have to change your filters more frequently than a location with l...

Страница 46: ...AND IS NOTREQUIRED Water in the hot circuit is not sanitary until the temperature exceeds 77 C 171o F for at least 5 minutes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin a...

Страница 47: ...off Draw a glass of cold water and verify it is has chilled to proper temperature Heater Test 22 Always ensure tanks are full of water before turning on the heater or the overheat High Limit will ope...

Страница 48: ...ater Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disablethe Heater and Compressor 2 Dispense 2 Litres gallon of water through the Hot Tank to cool thewate...

Страница 49: ...ld and Hot Tanks 8 Turn off the Red Heater and Compressor Power Switch O OFF to disablethe heater and compressor 9 Dispense 2 Litres 1 gallon of water through the hot tank to cool thewater temperature...

Страница 50: ...100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration syst...

Страница 51: ...Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOTTANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur within one minute an...

Страница 52: ...water in the Leak Tray and will shut down inlet solenoid Possible Reason Solution Water is present in the Bottom Tray causing the leak detection to trigger Leak Detection is on the Mini Model only Re...

Страница 53: ...dose of UV Check UV System 1 If Ballast Indication Light is Green the system should be operational Ensure UV lamp is on Replace Lamp If lamp is replaced and problem persists replace UV Sensor 2 If Ba...

Страница 54: ...Page 53 Revision EU05 07 17 3 FAULT CODE No LED Light Possible Reason Solution Power Problem Check for power disruption LED Light is out Check that the PCB LED is operational replace PCB as necessary...

Страница 55: ...or Power Switch won t light and the Red LED onthe Front won t light Possible Reason Solution Circuit Breaker Check the Circuit Breaker Fuse is Blown Replace Fuse Defective Loose Power Cord Check that...

Страница 56: ...place Front PCB Defective Red Heater Compressor Switch Replace Red Heater Compressor Switch 3 Compressor Runs But Does Not Chill Possible Reason Solution Condenser is dirty Clean the condensing coil o...

Страница 57: ...ed Heater Compressor Switch on I ON Compressor Starting Circuit Turn Red Heater Compressor Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black and red terminal co...

Страница 58: ...out of Faucet Vent Hole 7 Restricted Flow of Hot Water 8 Hot Water Drip out of Faucet 9 Dispenses Hot and Cold Water at the same time 10 No cold water available 11 Water does not dispense from unit 1...

Страница 59: ...solenoid to activate not button click Adjust water pressure to 2 7 4bar Loose or bad connection on the Front Dispensing PCGB or Solenoid Connector Check that they are connected properly and tightened...

Страница 60: ...ot button click Adjust water pressure to 2 7 4bar Bad Display PCB Replace Main PCB Part Number EN 6126 A Debris in the Solenoid Inspect Solenoid for debris and clean out as needed Dispensing Button St...

Страница 61: ...t and press the dispense button Does the solenoid open without water pressure to the unit Listen for solenoid to activate not button click Adjust water pressure to 2 7 4bar Improper tubing attachment...

Страница 62: ...the Waterlogic com website for more information Tubing is creased or has a kink in it Inspect and replace tubing as necessary Faucet nipple screen mesh has obstruction s Unscrew faucet nipple from fa...

Страница 63: ...in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the Hot Tank Outlet Tube that allows air and water to pass into the Vent...

Страница 64: ...ver Check Hot Solenoid Dispense cold water and visually inspect tubing for water flow from both tanks Check Cold Solenoid Disconnect Elbow from outlet of Cold Solenoid Select hot water and dispense qu...

Страница 65: ...onnection s on the Display PCB Turn power off unplug the WL2FW Water Treatment Systemand visually inspect solenoid connections into the Display PCB Verify the soldering points on connections are secur...

Страница 66: ...pply valve Open the water supply valve The unit is not properly plugged into electrical outlet Check electrical outlet connection or for blown circuit breaker Red Heater Compressor Switch button on un...

Страница 67: ...old wires on PCB red and blue connections If water now dispenses from the opposite side this is an indication that there is a PCB problem Replace PCB Solenoid If both the Water Pressure and PCB have b...

Страница 68: ...vate not button click Adjust water pressure to 2 7 4bar Cold or Hot Water solenoid valve malfunction Inspect valve components for proper function Replace as necessary Obstruction in solenoid housing i...

Страница 69: ...sure Regulator Should be 2 7 4bar Use Pressure Regulator The correct input water pressure is critical to the performance of the unit to allow solenoids to open Outgoing Flow Rate Verify the outgoing F...

Страница 70: ...ucet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On through the faucet a...

Страница 71: ...solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Protective Equipment Rubber or Nitrile Safety Gloves and...

Страница 72: ...produces Hot Water up to 87 C 187 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoidinjury CAUTION MUST REPLACE HOT...

Страница 73: ...out Run Compressor for at least ten minutes If Condenser is not warm then refill the refrigerant Compressor problem If Compressor is not running repair or replacement is needed Note The Waterlogic Fir...

Страница 74: ...have Extra Hot capability and the maximum hot temperature is 87 C 189 F It typically takes 10 minutes for the 500W to heat the 1 5 litre 0 4 Gallon of room temperature ambient water to the 85 C 185 F...

Страница 75: ...s gong to the hot tank confirm proper connections to the heating elements Hot tank life is 3 5 years depending on usage connected wire s to the Heating Element Hot Tank Heating Coil Not Heating Turn P...

Страница 76: ...ing any button wakes up the WL2FW Water Treatment System and turns the heater circuit back on The hot tank will typically take less than 10 minutes to heat the water from ambient to the 85 C 185 F set...

Страница 77: ...x on the rear of the Hot Tank Looking through the condenser coils on the rear of the unit you will see the Hot Tank located on the right hand side 5 From the front of the Water Treatment System reach...

Страница 78: ...top flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor Heater Switch I...

Страница 79: ...On the Energy Saver PCB Move the Jumper on JP9 from Pins 1 and 2 to Pins 2 and 3 Unplug Power Cord and remove Top Cover to access Energy Saver PCB WL2FW Water Treatment Systems comes with Hot and Cold...

Отзывы: