WL2 FW
Manual
Page 58 – Revision EU05-07-17
1.
Irregular / Intermittent Dispensing from One Side
Possible Reason
Solution
Too much water pressure.
Recommend 2.7 to 4 bar for
the
WL2FW Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of
the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without
water pressure to the unit? Listen for solenoid to activate, not
button “click”.
Adjust water pressure to 2.7-4bar.
Loose or bad connection on
the Front Dispensing PCGB or
Solenoid Connector
Check that they are connected properly and tightened.
Solenoid
If both the Water Pressure and PCB have been ruled out, then it is
the Solenoid.
Replace Solenoid.
Dispensing button is broken on
PCB
Check PCB for loose or damaged button. Replace PCB as
necessary.
2.
Hot Water Intermittently Forced Out Through the Faucet, or a Dual Stream Out of
the Faucet
Possible Reason
Solution
Mineral deposits on the
expansion slot inside the hot
tank vent chamber which
blocks the normal path of
water to expand.
Descale Hot Tank
See Hot Tank Descaling Instructions that are included further
below in this Troubleshooting Section.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...