WL2 FW
Manual
Page 69 – Revision EU05-07-17
17.
Run On – Water continues to dispense out of faucet after releasing the dispense
button
Reason
“Run On” or “Carry On” is present in all Waterlogic pressure fed units without outlet solenoids.
“Run On” is defined is the amount of water that continues to dispense out of the faucet after
releasing the dispense button.
Run On exists because the tanks pressurize as water is being dispensed. Every Waterlogic tank has an
outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the
faucet. The inlet solenoid controls flow into the tanks. The tanks will “depressurize” once the
dispense button is released the inlet solenoid closes. A small amount of water will “Run On” through
the faucet as the tank depressurizes to atmospheric conditions.
Typical “Run On” is 2-3 seconds.
“Run On” can be reduced by installing a pressure limiting device.
The amount of inlet or supply pressure directly impacts the amount of “Run On” as quantified below.
Waterlogic Lab Testing of Run On
Pressure
Pressure
Time
Flow Rate
Run On
Static Bar
Dynamic Bar
4 Litres
I/min
Seconds
4.6
2.7
61
2.9508197
3
3.4
2
72
2.5
2.5
2.2
1.3
92
1.956217
2
Pressure measured at inlet line to unit. Static with unit closed. Dynamic with unit
dispensing cold water.
No filters were installed in unit.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...