Page 49 – Revision EU05-07-17
INSTALLATION PROCEDURES
Safety and Installation Guidelines
Ensure all Local Laws and Codes including health and safety guidelines are met when installing
Waterlogic
Equipment. Only qualified service technicians should attempt installation and service of
Waterlogic
Equipment.
WARNING!
ELECTRICAL SHOCK HAZARD.
Always unplug (isolate from power supply) to prevent
electrical shock except where electrical tests are specified.
WARNING!
IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK.
Connect to a 13 amp 220/240V 50Hz properly grounded outlet (GFI is recommended). Ensure
polarity is correct and always use a 3-prong outlet. Consult a qualified electrician if you have any
questions.
WARNING!
ONLY USE A Waterlogic SUPPLIED POWER CORD.
Locate system within 1 meter of
power supply. Never use an extension cord or adapter. Do not use a damaged power cord or
plug. Keep power cord out of heavy traffic areas and away from heat sources. Do not, under any
circumstances, remove ground prong or alter the power cord. Never pull the power plug from the
outlet with a wet hand or allow the plug to get wet. Failure to use the supplied power cord will
void UL Certification and Warranty.
CAUTION!
INDOOR USE ONLY.
Never expose to direct sunlight, heat sources, or ambient air
temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures. Ensure there is adequate clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer environments
require more clearance around the unit. Minimum clearance around all surfaces of the machine is
50mm. Installs where the ambient temperature exceeds 27°C (80°F), require a minimum of
100mm clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Operating pressure must be 2.7 to 4bar. Be aware
of any potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold
water supply only. Feed water over 37°C (100°F) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to
the water supply and the electrical connections as possible.
WARNING!
STORE AND TRANSPORT UNIT EMPTY. ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
Pre-delivery and sanitization procedures as prescribed in this manual must be performed before
installing the
WL2FW Water Treatment Systems
.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...