RESETTING THE HOT TANK OVERHEAT OR HIGH LIMIT SAFETY
1.
Red Compressor/Heater Switch must be in the
O=OFF
position
2.
Unplug the Power Cord from rear of
WL2FW Water Treatment System.
3.
Free standing Model: Remove the Lower Front Panel by removing the Phillips Head
Screws underneath the Lower Front Panel.
Mini Model: Remove the Side Panel by removing Phillips Head Screws from Side Panel.
4.
Locate the Protective Metal Box on the rear of the Hot
Tank. Looking through the condenser coils on the rear
of the unit, you will see the Hot Tank located on the
right-hand side.
5.
From the front of the Water Treatment System, reach
up behind the hot tank and take hold of the protective
metal box covering the thermostat and overheat on the
hot tank.
There are nuts that secure the Protective Metal Box to
the Hot Tank, are loose enough to allow you to remove
the Protective Metal Box.
If the nuts on the metal box are too tight, loosen the
nuts securing the Hot Tank to the upper base of the
WL2FW Water Treatment System
unit and lower the
Hot Tank so you can remove the Protective Metal Box.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...