WL2 FW
Manual
Page 72 – Revision EU05-07-17
COLD WATER TROUBLESHOOTING INDEX
1.
Cold Water is not Cold 5°± -3°C (41°± 5°F)
Possible Reason
Solution
No power or refrigeration
elements
Check that the Red Heater & Compressor
switch is on.
Turn Red Heater & Compressor Switch on.
I = ON
Tank has run out of cold water.
Cold tank capacity is 4 Litres (1
Gallon) for Free standing and 2
Litres (½ Gallon) for Mini.
Wait for Cold Tank to chill water to temperature prior to
dispensing more cold water.
Greater capacity
Waterlogic Water Treatment Systems
are
available.
Cold Water Thermostat
Check continuity of Thermostat with multimeter. Replace
Thermostat as required.
Refrigerant has run out
Run Compressor for at least ten minutes. If Condenser is not
warm, then refill the refrigerant.
Compressor problem
If Compressor is not running, repair or replacement is
needed.
Note: The Waterlogic Firewall reduces 7-log of waterborne bacteria, 5-log of viruses, and 4-log of
parasites potentially found in the drinking water. A small amount (about 50ml) of water remains in
the Firewall device after dispensing. This water does not remain permanently chilled, and will
eventually become room temperature after several hours. To ensure the next glass of water
dispensed is adequately chilled, Waterlogic recommends dispensing 100ml or more cup of water
after long periods of inactivity. The first 50ml will be near room temperature, and the remaining
100+ml will be very cold. The mixture of these two temperatures will provide for an adequately
refreshing, cold drink.
Содержание WL2FL Free Standing
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...