background image

OPERATION AND INSTALLATION

Open vented (non-pressurised) small water heater

 

» SNE 5 t ECO GB

Содержание SNE 5 t ECO

Страница 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Страница 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Страница 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Страница 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Страница 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Страница 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Страница 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Страница 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Страница 9: ...INSTALLATION TEMPLATE...

Страница 10: ......

Страница 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Страница 12: ...NOTES...

Страница 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Страница 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Страница 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Страница 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Страница 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Страница 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Страница 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Страница 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...

Отзывы: