iNSTallaTiON 

 

Commissioning

www.stiebel-eltron.com 

SNE 5 t ECO GB| 

11

11.  Commissioning

 

WARNING Electrocution

Commissioning may only be carried out by a qualified 

contractor in accordance with safety regulations.

 

Note

During initial start-up and following prolonged power 

supply interruptions (approx. 8 hours), you must set the 

day of the week and the time.

11.1  Initial start-up

1.

2.

D

00000

49

32

5

f

f

Either open the DHW valve of the tap or set the mono lever 

mixer tap to "hot" until the water that flows out is free of air 

bubbles.

f

f

Insert the plug into the standard socket or set the fuse/MCB 

in the distribution board.

f

f

Select a temperature.

f

f

Check the entire hydraulic installation for tightness.

 

Note

If you fail to follow the correct sequence (first water, then 

power), the boil-dry protection check will respond.

Boil-dry protection

The appliance PCB carries out a boil-dry protection check during 

initial start-up and after every power supply interruption:

Red LED

Illuminates for 20 s Appliance heating up 

Red LED

40 s off

PCB evaluation

During the boil-dry protection check, the "Heating enabled" sym-

bol flashes and the backlighting is switched on.

 

Note

During the boil-dry protection check ...

 

- the appliance must not be separated from the power 

supply.

 

- no water may be drawn from the draw-off point.

Following a successful boil-dry protection check, the appliance 

maintains a set temperature of 55 °C.

 

Note

If the boil-dry protection check has responded, the fault 

code "E1" is displayed. Any repeat start-up is blocked for 

5 minutes.

Proceed as follows:

f

f

Fill the appliance with cold water.

f

f

After a blocking time of 5 minutes, the appliance carries out 

a new boil-dry protection check.

f

f

If the fault continues to be displayed, reset the appliance 

(P5 = on).

11.1.1  Appliance handover

f

f

Explain the functions of the appliance to the user. Show the 

user how to operate the appliance.

f

f

Make the user aware of potential dangers, especially the risk 

of scalding.

f

f

Hand over these instructions and, if applicable, the instruc-

tions for any accessories.

11.2  Recommissioning

See chapter "Installation / Commissioning / Initial start-up".

12.  Appliance shutdown

f

f

Isolate the appliance from the power supply by removing the 

plug or by tripping the MCB in the distribution board.

f

f

Drain the appliance (see chapter "Installation / Maintenance / 

Draining the appliance").

13.  Troubleshooting

problem

Cause

remedy

The appliance does 

not supply hot water. 

The high limit safety 

cut-out has tripped. 

Remedy the fault and replace 

the high limit safety cut-out as-

sembly (safety fuses).

 

 

The strainer in the cold 

water inlet pipe at the 

angle valve is blocked.

Clean / replace the strainer (see 

chapter "Installation / Mainte-

nance / Cleaning the strainer").

Loud boiling noises 

inside the appliance.

The appliance is scaled 

up. 

Descale the appliance. 

The tap drips for a 

while after it has 

been closed.

The residual water 

is not held in the tap 

outlet.

Replace the aerator in the tap 

outlet, the tap outlet or the tap. 

The tap drips when 

the appliance is 

heating up.

An unsuitable tap is 

being used. 

Replace the tap (see chapter 

"Installation / Appliance de-

scription / Accessories").

 

The anti-drip function 

is faulty.

Replace the appliance. 

Fault list

Faults are indicated by a rapid flashing of the red LED. The display 

shows the relevant fault code:

fault code

Cause

remedy

E1 

Boil dry 

See chapter "Commissioning / 

boil-dry protection".

E2 

Sensor break 

Sensor short circuit

Check the sensor contacts. Re-

place the sensor if necessary.

Содержание SNE 5 t ECO

Страница 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Страница 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Страница 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Страница 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Страница 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Страница 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Страница 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Страница 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Страница 9: ...INSTALLATION TEMPLATE...

Страница 10: ......

Страница 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Страница 12: ...NOTES...

Страница 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Страница 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Страница 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Страница 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Страница 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Страница 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Страница 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Страница 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...

Отзывы: