14. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
f
f
Dismantle the appliance for maintenance work.
14.1 Draining the appliance
WARNING Burns
Hot water may escape during draining.
f
f
Drain the appliance via its connectors.
14.2 Cleaning the strainer
D
00000
71
784
f
f
Detach the "cold water inlet" connection.
f
f
Using pliers, remove the strainer from the "cold water inlet"
connection.
f
f
Descale or replace the strainer.
14.3 Opening the appliance
Material losses
Incorrect handling can damage the BUS connection be-
tween the programming unit and the main PCB.
f
f
Carefully pivot the appliance cover when opening.
D
00000
71
79
4
f
f
Open the appliance cover by lowering the bolt screws in-
wards and pivot the cover upwards, then remove it.
Material losses
f
f
When closing the appliance, stow the BUS cable in
the recess provided in the thermal insulation.
14.4 Descaling the appliance
!
Material losses
Never treat the cylinder surface with descaling agents.
f
f
Remove the flanged immersion heater.
f
f
Carefully tap the heating element to remove coarse limescale
deposits.
f
f
Immerse the heating element up to the flange plate in desca-
ling agent.