background image

Installation & Operating Instructions

Birko TempoTronic Over-Sink Boiling Water Heaters (

from September 2008).

Page 1

OVERSINK BOILING WATER

Boiling water always on tap in kitchens large or small.

Key Features

Choice of models delivering 15 to 150 cups of boiling water at one time.

Choice of white steel case or stainless steel case at no additional cost.

Stainless steel tank for minimal maintenance.

Can be supplied with an external five-micron filter as an optional extra.

Installation with an approved external water filter is strongly recommended.

Key Specifications

Note:

 Cup size is 167 ml. Installation with an external water filteris recommended for protection of the Heater 

and users. Installation of a water filter inhibiting the accumulation of mineral scale is essential in known hard 
water areas and a sediment filter is essential where water contains excessive sediments.

Please Read These Warnings First

      Read all installation instructions and precautions before installing the heater.

Never attempt to install any heater without reading all of the instructions.

All plumbing connections must be made in accordance with AS/NZS3500.

In hard water areas where mineral scale accumulation in the boiling chamber of the heater may become a 
problem, consideration should be given to the maintenance required.

Do not use jointing paste on plumbing fittings - use only Teflon Tape.

This appliance is not intended for use by persons (Including Children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for their 
safety.

Children should be supervised to ensure they do not play with the appliance

If the power supply cord is damaged it must be replaced by a Birko Service Provider or qualified technician.

Do not remove the cover of the heater under any circumstances without first isolating the heater from the 
power supply.

Do not use strong, corrosive or abrasive cleaners to clean the exterior. 

Frost protection: If this heater is located where ambient air temperature could fall below 5ºC when the 
heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same 
protection to the connecting pipework and fittings.

The ambient temperatures this unit should operate with is 5ºC - 50ºC.

Positioning 

Mount the heater in a vertical position over a draining board or sink.

Tap outlet should be > 200 mm and < 600 mm above the draining board. 

Avoid installation in any area where heater is exposed to excessive steam.

Minimum operating water pressure is 200 kPa, maximum 1000 kPa. (0.2mPa - 1.0mPa)

Do not install where water is microbiologically unsafe or of unknown quality.

Do not install in an area that may be cleaned by a water jet.

Not for outdoor use.

C

B

D

E

A

Model

2.5L

5L

7.5L

10L

15L

20L

25L

Boiling water delivery (cups)

15

30

45

60

100

120

150

Boiling water capacity (litres)

2.5

5

7.5

10

15

20

25

Boiling water recovery (cup/hour)

120

120

120

120

120

120

120

Boiling water element (amps)

10

10

10

10

10

10

10

Supply voltage (volts)

220-240

220-240

220-240

220-240

220-240

220-240

220-240

Minimum water pressure (bar)

2

2

2

2

2

2

2

Maximum water pressure (bar)

10

10

10

10

10

10

10

Overall height A (mm)

430

510

510

565

565

630

630

Overall width B (mm)

315

365

365

425

425

490

490

Depth including tap C (mm)

210

240

240

310

310

340

340

Depth cabinet only D (mm)

125

170

170

240

240

270

270

Tap centre to unit base E (mm)

185

160

160

160

160

170

170

Содержание TempoTronic 2.5L

Страница 1: ...heir safety Children should be supervised to ensure they do not play with the appliance If the power supply cord is damaged it must be replaced by a Birko Service Provider or qualified technician Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the exterior Frost protecti...

Страница 2: ...s installed replace the heater cover and fit the tap To fit the tap screw it clockwise into the socket a maximum of 4 full turns If tap is not completely tight remove and fit more sealing tape before refitting Turn on the water and check all connections for leaks Turn on the power and wait 20 minutes before using Priming Mode When the power is turned on for the first time the unit will prime itsel...

Страница 3: ...t steam vent O Flow Spare Parts 1 7 30mm 85mm 65mm 45mm Reducer 1 2 BSP Olive Compression Union FRONT VIEW SIDE VIEW 55mm 9a Water Outlet Fitting half inch BSP 9b 1311056 Tap Assembly 10 Sensor Red tip minimum water level 11 Sensor White tip maximum water level 13 Maximum Water Level 14 1310842 Power Cord Plug Assembly 15 1311042 Tempo Tronic PCB Assy 16 1311057 Tap Cup Seal 17 1311064 Tap Insert ...

Страница 4: ...ectly Please contact your local city council for collection centre details Regulatory compliance mark Birko Heaters Australia Pty Ltd ABN 39 103 881 625 67 Allingham St Condell Park N S W 2200 AUSTRALIA Local Ph 1300 724 955 Local Fax 1300 735 259 sales birkoheaters com www birkoheaters com The term Birko is a registered trade mark of Birko Heaters Australia Pty Ltd 6001007 January 2013 v1 01 ...

Отзывы: