background image

Installation & Operating Instructions

Birko TempoTronic Over-Sink Boiling Water

Page 3

OVERSINK BOILING WATER

17

16

18

Teflon Tape

9b

Ref

Part No

Description

1

1311010

Water Solenoid Valve

2

1311044

Condenser Assembly

3

Cold Water Inlet (half inch BSP)

4

1311043

Thermistor Steam Sensor

5a

Element & Tank Assembly

5b

1311032

Element Assembly 5 to 25 Litre

6

1311006

Manual Rest Thermostat (boil dry protection)

7

Steam Vent Outlet (half inch BSP)

8

1311125

Manual Reset Thermostat (steam vent O/Flow)

Spare Parts

1

7

30mm

85mm

65mm

45mm

Reducer 1/2” 
BSP
(Olive Compression Union)

FRONT VIEW

SIDE VIEW

55mm

9a

Water Outlet Fitting (half inch BSP)

9b

1311056

Tap Assembly

10

Sensor - Red tip   (minimum water level)

11

Sensor - White tip (maximum water level)

13

Maximum Water Level

14

1310842

Power Cord & Plug Assembly

15

1311042

Tempo Tronic PCB Assy

16

1311057

Tap Cup Seal

17

1311064

Tap Insert

 

2.5L

5-75L

10-15L

20-25L

A

56.4

41.4

41.4

41.4

B

198.0 278.0

335.0

399.0

C

418.45

488.45

545.45

609.45

D

42.45

42.45

42.45

42.45

E

143.4

143.4

143.4

143.4

F

200

H

430.8

500.8

557.8

621.8

Wall Mounting Dimmensions (mm)

2.5- 15L

20-25L

Washer

15

14

2

7

6

5

3

1

11

10

13

9a

8

4

Содержание TempoTronic 2.5L

Страница 1: ...heir safety Children should be supervised to ensure they do not play with the appliance If the power supply cord is damaged it must be replaced by a Birko Service Provider or qualified technician Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the exterior Frost protecti...

Страница 2: ...s installed replace the heater cover and fit the tap To fit the tap screw it clockwise into the socket a maximum of 4 full turns If tap is not completely tight remove and fit more sealing tape before refitting Turn on the water and check all connections for leaks Turn on the power and wait 20 minutes before using Priming Mode When the power is turned on for the first time the unit will prime itsel...

Страница 3: ...t steam vent O Flow Spare Parts 1 7 30mm 85mm 65mm 45mm Reducer 1 2 BSP Olive Compression Union FRONT VIEW SIDE VIEW 55mm 9a Water Outlet Fitting half inch BSP 9b 1311056 Tap Assembly 10 Sensor Red tip minimum water level 11 Sensor White tip maximum water level 13 Maximum Water Level 14 1310842 Power Cord Plug Assembly 15 1311042 Tempo Tronic PCB Assy 16 1311057 Tap Cup Seal 17 1311064 Tap Insert ...

Страница 4: ...ectly Please contact your local city council for collection centre details Regulatory compliance mark Birko Heaters Australia Pty Ltd ABN 39 103 881 625 67 Allingham St Condell Park N S W 2200 AUSTRALIA Local Ph 1300 724 955 Local Fax 1300 735 259 sales birkoheaters com www birkoheaters com The term Birko is a registered trade mark of Birko Heaters Australia Pty Ltd 6001007 January 2013 v1 01 ...