Parameterizing
WAGO-I/O-SYSTEM 750
750-636/000-x00 DC Drive Controller 24V/5A
Manual
Version 2.1.0
Pos: 36.5 /Serie 750 (WAGO-I/O-SYST EM)/In Betrieb nehmen/Parametrier en über Parameter kanal/Parametrier en 750-0636_Parameter-Datensätze @ 18\mod_1391170590486_21.docx @ 144092 @ 23444334443444 @ 1
8.2
Parameter Records
8.2.1
Available Parameter Records
The I/O module has three different parameter records.
Figure 41: Parameter Records 1… 3
Table 31: Table Name
Record
Number
Description
Description
1
Actual
Current parameters used by the I/O module
2
User Settings
Custom-specific parameter settings
3
Factory Default
Manufacturer-specific parameter settings
8.2.1.1 Actual (1)
The parameter record Actual (1) contains the parameters used by the I/O module.
The parameter record Actual (1) is copied 1:1 from the parameter record User
Settings (2) upon system start of the I/O module, i.e. after power-up or reset of the
I/O module.
8.2.1.2 User Settings (2)
The parameter data set User Settings (2) offers the users the option to permanently
store parameters made at runtime to the I/O module and to reload them, if
necessary.
8.2.1.3 Factory Default (3)
The parameter data set Factory Default (3) offers the users the option to load a
parameter set that allows for a predefined operating state of the I/O module, if
necessary.