74
Parameterizing
WAGO-I/O-SYSTEM 750
750-636/000-x00 DC Drive Controller 24V/5A
Manual
Version 2.1.0
Pos: 36.13 /Serie 750 ( WAGO-I/O-SYST EM)/In Betri eb nehmen/Par ametrieren über Par ameter kanal/Parametrier en 750- 0636_I/O-M odul-spezifische Par ameter daten @ 18\mod_1391416278710_21.docx @ 144194 @ 23333333333333333 @ 1
8.6
I/O Module-Specific Parameter Data
The following parameters and parameter addresses are defined for the I/O module
750-636/000-x00 (DC Drive Controller 24V/5A):
Table 38: 2.2
I/O Module-Specific Parameter Data
Parameters
Description
Parameter
address:
Register
RampTime_START
Length of the start ramp
0
35
RampTime_STOP
Length of the stop ramp
Prestop_Pos
Prestop value for approach in positive
direction
1
36
Prestop_Neg
Prestop value for approach in negative
direction
2
37
Target_Window
"Setpoint position" tolerance range
3
38
Standstill_Limit
"Standstill" maximum speed
4
39
EnginePowerSupply
Selection of motor voltage
IncScale
1x, 2x or 4x evaluation of quadrature
pulses
Positioning_Retry
Maximum number of retries
Z_Input_Enable
Enabling the Z input for the preset
function
Stop-Mode_PwrUp
Stop mode in the absence of supply
voltage
PresetValue
Preset value (HighWord)
5
40
Preset value (LowWord)
6
41
Overtravel
Distance and direction for gearbox
backlash compensation
7
42
Triggermode_Inputs
Input sensitivity of digital inputs
8
43
Stop-Mode
Selection of Stop mode
DirectionReversal
_Delay
Delay of direction reversal
Filter_Time
Debouncing times of digital inputs
9
44
ShutDown_Distance
Starting distance CurrentControl_PWM
(HighWord)
10
45
Starting distance CurrentControl_PWM
(LowWord)
11
46
CurrentLimit_PWM
Pulse-duty factor for PWM signal
12
47
CurrentControl_PWM
Pulse-duty factor for PWM signal
CurrentLimit_Time
ON time of CurrentLimit_PWM
13
48
MotionDetection
Timeout
Maximum delay until the first incremental
encoder pulse