CAUTION
Leakage current in the event of a fault!
In the event of a fault, there can be a leakage current of 28 mA at the
outputs (A+ / A-). This must be taken into account for safety considerations
in the event of a fault for the 750-636/000-800 I/O module!
Pos: 38.6 /Serie 750 (WAGO-I/O-SYST EM)/Einsatz in sicherheitsg erichteten Anwendung en/Allgemeiner Aufbau ei ner Potenti algruppe - r ückwir kungsfr eie Vari anten @ 6\mod_1258973074755_21.docx @ 44664 @ 23 @ 1
9.2
Connecting the I/O Module to Safety Switching
Devices or F I/O Modules
9.2.1
General Structure
When using the interference-free variant “…/xxx-8xx”of the I/O module 750-
636/000-x00 in safety related applications, the modules belonging to a safety
switching device shall be combined to form a potential group. Power to the
potential group shall be supplied via a power supply module 750-601 or 750-602
or via filter module 750-626. Either a power supply module or a separation
module without power jumper contacts (750-616) must be connected at the end of
the potential group.
Pos: 38.7 /Serie 750 (WAGO-I/O-SYST EM)/Einsatz in sicherheitsg erichteten Anwendung en/Aufbau einer Potenti algruppe @ 6\mod_1259221280455_21.docx @ 45332 @ @ 1
Figure 43: Potential Group for Safety Related Applications
Pos: 39 /D okumentation allgemei n/Glieder ungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1