4.5 - GREEN MACHINE
™
- North America - Installation, Operation, Maintenance, & Troubleshooting Manual
Chapter 4: Control Panel
Page 72
A
larm Screen, continued…
•
Maintenance Switch Alarm:
•
The Maintenance Switch is used when we want power to the VST Control Panel, but
do not want the GREEN MACHINE to operate.
•
The GREEN MACHINE will not operate during this alarm.
•
The Maintenance Switch Alarm will occur:
•
When the Maintenance Switch is turned OFF, the GREEN MACHINE will not
operate and the switch will show as an active alarm.
•
To remove the Maintenance Switch Alarm, turn the switch to ON.
•
Overfill Alarm:
•
An Alarm will occur:
•
Whenever there is a UST gasoline overfill at the station, the VST Control Panel is
configured to alarm.
•
If an overfill alarm activates while a test is running:
•
The test will terminate.
•
The Alarm will display RED, OVERFILL ACTIVE.
•
The GREEN MACHINE will NOT operate during this Alarm.
•
SD Micro Card Alarm:
•
An Alarm will occur:
•
If the card is not installed or installed incorrectly.
•
After the card is installed, the Alarm will clear and Normal (Green).
•
The GREEN MACHINE will operate during this Alarm.