4.5 - GREEN MACHINE
™
- North America - Installation, Operation, Maintenance, & Troubleshooting Manual
Chapter 8: Troubleshooting
Page 123
8.4.1
Control Panel General Information
•
The VST Control Panels are pre-wired and tested prior to leaving the
factory.
•
Check all wiring connections to make sure they are properly connected.
•
The VST Control Panel is MET Listed to comply with UL Standard 508A,
and CSA C22.2 No.14.
•
If an electrical component has malfunctioned inside the VST Control
Panel, all the electrical components MUST BE ordered from the
Replacement Parts List (Chapter 9) in this manual.
•
Check the wire terminals 02011 and 02032, then proceed to the appropriate
procedures:
Option 1
: If there are two wires landed in these terminals, the VST Control Panel
is powered directly from the distribution panel. See Section 8.4.2.
Option 2
: If there is a jumper connecting these terminals, the VST Control Panel is
powered through an ESO breaker. See Section 8.4.3.