74
Components
Room temperature sensor,
part no. 7408 012
(cont.)
Checking room temperature sensor
1.
Disconnect the wires from the
sensor.
2.
Check the sensor resistance at
terminals 9 and 13b.
3.
Compare the measurement with
the actual temperature (for
scanning, see page31).
Check the installation and replace
sensor, if necessary, in case of
severe deviation.
Specification
Protection:
IP 30
Permiss. ambient
temperature
H
in operation:
0 to + 40
º
C
H
during storage
and transport:
20 to + 65
º
C
5862700GB
0
R
esistance in
500
5
10
15
20 25 30 35 40
510
520
530
540
550
560
570
580
600
590
Room temperature in
º
C