10
Installation
Summary of electrical connections
(cont.)
Plug 230 V~
sÖ
Heating circuit pump A1
(accessory)
sÖ
Heating circuit pump mixer
circuitM2 (accessory)
sA
Cylinder primary pump
(accessory)
sK
DHW circulation pump (on site)
fÖ
Mains power connection
fA
Burner
gS
Mixer motor (accessory)
X12 External burner start (stage1)
Low voltage plug
!
Outside temperature sensor
?
Flow temperature sensor
(accessory)
§
Boiler temperature sensor
%
Cylinder temperature sensor
aG
Flue gas temperature sensor
(accessory)
aJ
Return temperature sensor
(accessory)
aVG
KM BUS user or distributor
(accessory)
a:A
Two−stage/mod. burner
extension (part of the standard
boiler delivery)
When connecting external switching
contacts or components to the
protective low voltage of the control
unit, please observe the safety
requirements of protection class II,
i.e. 8.0 mm air gap/creeping distance
or 2.0 mm insulation thickness from
’live’ components.
Ensure a safe electrical separation
for all on−site components (incl.
PC/laptops) to EN60335 or IEC65.
5862700GB
Содержание Vitotronic 200 KW2
Страница 22: ...22 Installation Installing the top part of the control unit 5862 700 GB 7 5 1 4 6 2 3 ...
Страница 23: ...23 Installation Opening the control unit 5862 700 GB 3 2 1 ...
Страница 104: ...104 Coding 5862 700 GB ...
Страница 106: ...106 Parts list Parts list cont 5862 700 GB 070 010 042 043 065 019 020 018 074 013 015 074 040 041 ...
Страница 108: ...108 Connection and wiring diagram Connection and wiring diagram 5862 700 GB F2 4A slow 250V F1 slow 6 3A 250V ...
Страница 118: ...118 5862 700 GB ...
Страница 119: ...119 5862 700 GB ...