66
Yes
Automatic calibration of
the combustion controller
No
Fault E3
Ensure adequate heat trans-
fer. Press reset button
R
.
Fault Eb
Check gap between ionisa-
tion electrode and burner
gauze assembly.
Check allocation of gas type
(coding address 82, gas train
setting).
Check flue system; remedy
flue gas recirculation if re-
quired.
Press reset button
R
.
For further details regarding faults, see page 115.
Preparing the fuel cell module for commissioning
Checking the power supply
A
Fig. 65
1.
Check that the power supply has been connected
according to the details on page 39.
2.
Removing the front panel (if it is still attached); see
page 52.
3.
Ensure that ON/OFF switch
A
on the fuel cell
module is switched OFF (
0
).
4.
Switch on the power supply at the sub-distribution
board.
Programming unit on the fuel cell module
All settings for commissioning and maintenance are
made using the programming unit on the fuel cell mod-
ule.
Commissioning, inspection, maintenance
Function sequence and possible faults (gas…
(cont.)
5775 636 GB
Содержание C3TB
Страница 44: ...44 3 5 1 2x 2 4 7 6 Fig 43 Installation sequence Fitting the front panels 5775 636 GB Installation ...
Страница 48: ...48 14 Fig 47 Installation sequence If required for easier handling Dismantling cont 5775 636 GB Installation ...
Страница 136: ...136 Troubleshooting Repairs gas condensing module cont 5775 636 GB Diagnosis ...
Страница 143: ...143 Parts lists Heat cell assembly 5775 636 GB Components ...
Страница 148: ...148 0001 0001 0003 0003 0002 0002 0004 Fig 118 Parts lists External connection assembly 5775 636 GB Components ...
Страница 154: ...154 0006 0003 0005 0001 0002 0004 Fig 121 Parts lists Miscellaneous assembly 5775 636 GB Components ...
Страница 160: ...160 Parts not shown 0009 PCB IU100 B30 Parts lists Fuel cell assembly 5775 636 GB Components ...
Страница 161: ...161 Parts lists Fuel cell assembly cont 5775 636 GB Components ...
Страница 187: ...187 5775 636 GB ...