129
Checking the return temperature sensor
A
Fig. 102
10
1
10 30 50 70 90 110
Temperature in °C
0.4
0.6
0.8
2
4
6
8
20
Resistance
in kΩ
Fig. 103 Sensor type: NTC 10 k
Ω
1.
Pull leads from return temperature sensor
A
.
2.
Check sensor resistance and compare it to the
curve.
3.
In the event of severe deviation replace the sensor.
Danger
The return temperature sensor is in direct
contact with the heating water (risk of scald-
ing).
Drain the boiler on the heating water side
before replacing the sensor.
Troubleshooting
Repairs (gas condensing module)
(cont.)
5775 636 GB