XX002 Rev 799 Surveyor99 Dome System
Maintenance
••••
49
Maintenance
The Surveyor99 requires no scheduled maintenance; however, the Lower Domes require occasional cleaning.
Care and Cleaning of Metallized Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface, as acid in a
fingerprint can etch the coating. Use the recommended cleaning procedure in Step 4.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean, dry pressurized air.
3. If spots, streaks or stains appear on the exterior, they can be removed by rinsing with clean water and
drying with clean, dry pressurized air. Do not rub the inner surface.
CAUTION: Rubbing the inner surface of the metallized Lower Domes can cause permanent scratches.
4. If wiping is necessary, use a wick. Make a wick by rolling a section of soft paper towel into a tightly wound
tube and tear it in half. Moisten the torn edge of the wick with a solution of mild soap and water. Hold the
Lower Dome upside down and gently wipe the surface from the inside to the outer edge. Then, rinse with
clean water and dry with clean, dry pressurized air.
5. Clean the Lower Dome's exterior with any soft cleaning cloth and a mild glass cleaner suitable for acrylic
plastic.
Care and Cleaning of Clear Acrylic Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean dry pressurized air.
3. If spots, streaks or stains appear on the exterior, they can be removed with a solution of mild soap or
isopropyl alcohol and water using a lint-free soft paper towel. Dry with clean, dry pressurized air.
4. Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft
cleaning cloth.
CAUTION: Excessive rubbing of the Lower Dome surface can cause permanent scratches.
5. Clean all surfaces with any soft cleaning cloth and a mild glass cleaner suitable for acrylic plastic.
Fuse Replacement
Two fuses (F1 and F2) are located on the Communication/Power Supply Board. When necessary, replace
them with the following Fuse values:
F1: 2AG, 1.25 amp, 250 volt, slo-blo
F2: 2AG, 2.5 amp, 250 volt, slo-blo
Содержание Surveyor 99
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...